Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0372
E

Unsealed Penetrations in Smoke Barrier Walls

Philadelphia, Pennsylvania Survey Completed on 01-21-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain smoke barrier walls free of unsealed penetrations, which is a requirement for ensuring a 1/2-hour fire resistance rating. During an observation on January 21, 2025, at 10:55 a.m., it was noted that in the basement, next to the upper garage elevator, there were penetrations around data wires and a sprinkler pipe. This deficiency was confirmed during an exit interview with the Executive Director of Construction and Ancillary Services on the same day at 1:15 p.m.

Plan Of Correction

- ED of construction to Inservice supervisor of Plant Operations on policy and procedure for maintaining smoke barrier walls. - Penetration filled using 3M fire barrier sealant FD 150 + Red color and CP 25 WB+. - Supervisor of Plant Operations or delegate to complete audits 3x per week x 4 weeks to compliance with policy and procedure. - Audit findings will be submitted to QAPI committee monthly for review and recommendations as needed.