Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0372
F

Deficiencies in Fire/Smoke Barrier Construction

Vero Beach, Florida Survey Completed on 04-30-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain their fire/smoke barrier construction in accordance with NFPA 101 standards. During a fire safety tour conducted on April 30, 2025, several deficiencies were observed in the smoke barriers of the facility. Specifically, the Reflection Wing's 1-hour smoke wall near Room 106 had five penetrations above the ceiling, and near Room 104, there were three penetrations. Additionally, the Seaway Wing's 2-hour fire-rated wall near Room 206 had four penetrations above the ceiling. These penetrations in the smoke barriers compromise the integrity of the fire resistance rating, which is crucial for restricting the movement of fire and smoke in the event of an emergency. The Plant Operations Technician acknowledged these findings during the inspection, and the issues were communicated to the Administrator and the Director of Plant Operations during the exit conference. The report emphasizes that these examples are not exhaustive, and a thorough inspection of each barrier should be conducted to ensure all penetrations are identified and properly sealed. The penetrations in fire-rated barriers must be sealed with a UL-listed approved system to restore the original fire or smoke-rated integrity of the walls, ceilings, and floors.

Plan Of Correction

No residents were affected by this alleged deficient practice as of 05/16/2025 and none can be identified as of 05/16/2025. The maintenance director and assistants were educated by the Executive Director on 05/16/2025 on K372. The center smoke walls were inspected above the ceilings throughout the center on 05/16/2025 to identify any other penetrations needing to be sealed by the maintenance director/designee. 1. The Reflection Wing 1-hour smoke wall, near Room 106, had the five penetrations above the ceiling repaired on 05/20/25 by the maintenance director/designee. 2. The Reflection Wing 1-hour smoke wall, near Room 104, had the three penetrations above the ceiling repaired on 05/20/25 by the maintenance director/designee. 3. The Seaway Wing 2-hour fire rated wall, near Room 206, had the four penetrations above the ceiling repaired on 05/20/25 by the maintenance director/designee. Fire penetrations above the ceiling will be audited for compliance with K372 by the maintenance director/designee weekly x4 weeks, monthly x6 months and the results of these audits will be brought to QAPI for review. No residents were affected by this alleged deficient practice as of 05/16/2025 and none can be identified as of 05/16/2025. The maintenance director and assistants were educated by the Executive Director on 05/16/2025 on K372. The center smoke walls were inspected above the ceilings throughout the center on 05/16/2025 to identify any other penetrations needing to be sealed by the maintenance director/designee. 1. The Reflection Wing 1-hour smoke wall, near Room 106, had the five penetrations above the ceiling repaired on 05/20/25 by the maintenance director/designee. 2. The Reflection Wing 1-hour smoke wall, near Room 104, had the three penetrations above the ceiling repaired on 05/20/25 by the maintenance director/designee. 3. The Seaway Wing 2-hour fire rated wall, near Room 206, had the four penetrations above the ceiling repaired on 05/20/25 by the maintenance director/designee. Fire penetrations above the ceiling will be audited for compliance with K372 by the maintenance director/designee weekly x4 weeks, monthly x6 months and the results of these audits will be brought to QAPI for review.