Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0341
F

Improper Installation and Obstruction of Fire Alarm System Components

Battle Creek, Michigan Survey Completed on 05-08-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to ensure that the fire alarm system was installed and maintained in accordance with NFPA 70 and NFPA 72 standards. During an observation, it was found that the smoke detector head at the North Smoke Doors exit into the administration hall was not properly mounted to the ceiling. Additionally, another smoke detector head located in the North Mechanical closet was discovered with a plastic bag taped over it. These deficiencies were confirmed through interviews with the Facility Maintenance Director at the time of the observations. No information regarding specific residents, their medical history, or their condition at the time of the deficiency was provided in the report.

Plan Of Correction

K3411. The Maintenance Director and/or designee will repair the smoke detector heads at the North smoke doors and North mechanical closet. The Administrator will review regulation K341 and provide education to the Maintenance team on the requirements. The Maintenance Director and/or designee will conduct a weekly community audit of smoke detectors to ensure appropriate function. Results of the audits will be brought to the Quality Assurance Performance Improvement meeting monthly for review. The Committee will be responsible for any changes to the auditing process. The Administrator is responsible to attain and maintain compliance. Completion date for compliance will be 06.20.25.