Respiratory Care and Oxygen Equipment Not Provided as Ordered or Properly Maintained
Summary
The facility failed to provide required respiratory care and services for multiple residents who were receiving oxygen therapy or CPAP therapy. Surveyors observed several residents with oxygen tubing, humidifiers, nebulizer tubing, or storage bags that were not dated and labeled as required by the facility’s own policies. In multiple instances, tubing that should have been stored in a bag when not in use was observed hanging on equipment, coiled on a wheelchair, or otherwise left outside the storage bag. The facility’s policy also required oxygen equipment not in use to be protected from dust and dirt, and staff acknowledged that the tubing and storage bags should be labeled and changed weekly. For one resident, oxygen was being administered at 3 liters per minute even though the physician’s order called for 2 liters per minute. For another resident, oxygen was being administered at 3 liters per minute when the order called for 4 liters per minute, and the resident stated she was receiving 4 liters per minute. Surveyors also found residents receiving oxygen without a documented physician’s order for that therapy. One resident’s record showed no order for oxygen use even though oxygen was in place at the bedside, and another resident’s record likewise lacked an order for oxygen therapy despite the resident receiving oxygen through a nasal cannula. The facility also failed to obtain a physician’s order for CPAP machine settings for one resident. The resident stated the CPAP machine had been brought from home and used at night, while the record only showed an order for hours of use and did not include the oxygen concentration, duration, flow, or PEEP pressure as referenced in the facility’s policy and manufacturer guidance. In addition, surveyors observed a resident’s oxygen tubing touching the floor, a humidifier without a date label, and the absence of a posted no-smoking sign outside the room. Another resident’s humidifier, nasal cannula, and storage bag were observed without dates or labels, and a nonsampled resident’s oxygen humidifier was also observed without a date label.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.