Failure to Measure and Document PICC/Midline Line Position and Arm Circumference
Summary
The facility failed to provide care and services for PICC/midline lines for two residents, including failure to assess and document catheter length and arm circumference as outlined in the care plans and referenced standards. For Resident #18, who was admitted with diagnoses including benign prostatic hypertrophy, bladder cancer, and UTI, the MDS and admission assessment coded the resident as cognitively intact with a BIMS score of 14 out of 15 and identified a midline IV access. The physician order directed staff to observe the midline insertion site and surrounding areas and monitor for infiltration, bruising, pain, and signs and symptoms of infection. Resident #18’s comprehensive care plan directed weekly measurement of the arm circumference 3 inches above the insertion site and the length of the catheter from the insertion site to the tip, with documentation and notification of the MD if swelling or migration was noted. Review of the TAR failed to show documentation of these measurements. During interview, LPN #9 stated that during weekly dressing changes she looked for redness, swelling, and whether the line was intact, but she had never measured the PICC line or the arm circumference and had never seen the care plan intervention before. The facility policy on care and maintenance of central venous catheters also did not evidence documentation related to measuring catheter length. For Resident #19, the MDS admission assessment showed the resident was receiving IV medications, and physician orders directed weekly and PRN dressing changes, weekly needless cap changes, and assessment each shift for infiltration, bruising, swelling, pain, and signs or symptoms of infection. The care plan identified the resident as having a PICC line for antibiotic/IV treatment for a leg infection. Interviews with LPN #9 and RN #1 confirmed that staff changed dressings, assessed the site, and used the SASH protocol, but did not measure the PICC catheter ports or the arm circumference unless an order specifically required it. The physician orders for this resident also did not evidence an order to measure the exposed catheter ports or arm circumference.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.