F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
D

IV Fluids Not Initiated and Monitored per Order

Ignite Medical Resort ChestertonChesterton, Indiana Survey Completed on 07-28-2026

Summary

The facility failed to ensure safe, appropriate administration of IV fluids for one resident receiving parenteral fluids. During an observation, an RN found blood in the IV tubing while the resident was lying in bed with 0.9% normal saline infusing at 60 cc/hour into a peripheral IV in the right forearm. The RN disconnected the tubing and flushed the line with 10 cc of normal saline without using an alcohol prep pad on the port, then replaced the IV bag and tubing, primed the tubing, and reattached it. The RN later stated she did not use the alcohol prep pad because it was a closed system. Record review showed the resident had dehydration and had been ordered IV fluids on 7/21/26, but there was no documentation that the peripheral IV had been initiated before transfer to the hospital or upon return, no documentation that the IV had been discontinued after the initial bag infused, and no documentation of flush orders or dressing changes. A later order for 0.9% normal saline at 60 cc/hour every shift was entered on 7/26/26, and the MAR showed the fluids were started that night, but there were no documented assessments of the insertion site after the infusion began. The facility policy required verification of the order and indication upon insertion and assessment of the site each shift, before and after medication administration, and during continuous infusions.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0694 citations
Failure to Include PICC Line Care and Management
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Failure to Include PICC Line Care and Management: A resident with pneumonitis, stroke, and hemiplegia had a PICC line observed in the L upper arm, but the admission orders and care plan did not include PICC line care and management. Facility policy required a prescriber order with specific flushing/locking details and documentation of the procedure, and an RN later confirmed the omission.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Obtain IV Therapy and Flush Orders
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Failure to obtain physician orders for IV therapy and flush orders affected two residents. One resident had a midline IV for osteomyelitis and was receiving Meropenem, but there was no documented flush order or evidence the line was flushed before and after med administration. Another resident had an IV heparin lock in the forearm, but the MAR showed no physician order for IV therapy and no flush orders; the DON confirmed the orders should have been obtained.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Wrong enteral feeding formula given to two residents
E
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Wrong enteral feeding formula was given to two residents with feeding tubes. One resident with diabetes mellitus and respiratory failure was ordered Nutren 2.0, and another resident with respiratory failure and dysphagia was ordered Isosource 1.5, but staff switched the formulas and administered them to the wrong residents. Interviews confirmed the error, and staff stated LPNs were responsible for checking the physician order and giving enteral feeds one resident at a time.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain IV Flush Orders for a Resident with a Peripheral IV
E
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with dementia, DM2, and chronic venous insufficiency had a PIV and IV medication orders, but the IV flush orders were discontinued while the catheter remained in place. The MAR and order summary showed no current flush orders, and an LPN stated he did not flush the IV because there were no physician orders. The DON verified the flush orders were discontinued and said the IV should have been discontinued at the same time.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Line Dressing Not Changed Within Required Interval
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

PICC Line Dressing Not Changed Within Required Interval: A resident with a PICC line, severe sepsis, and septicemia had an IV dressing on the right arm that remained dated beyond the expected 7-day change interval while receiving IV vancomycin. The resident was unsure how often the dressing should be changed, and both an LVN and the DON stated PICC dressings are expected to be changed every 7 days or as needed if soiled.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Loose Midline Catheter Dressing Not Changed Per Policy
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with dehydration, thrombocytosis, viral pneumonia, and severe cognitive impairment had a midline IV access for continuous therapy, but the dressing was observed loose and dated beyond the weekly change interval. RNs stated the dressing should have been changed weekly and PRN if loose, but it was not changed because the bio patch supply had run out. The QAN and DON confirmed the dressing was overdue and that facility policy required weekly transparent dressing changes and antimicrobial disc changes every 7 days and PRN.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Indiana

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Indiana — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.