Infection Control Failures During Tracheostomy Care, Meal Service, and Contact Precautions
Summary
Sterile equipment was not ensured during tracheostomy care for one resident with a tracheostomy, gastrostomy status, nontraumatic intracerebral hemorrhage, and left hand contracture. The resident’s record showed intact cognition and supervision needs with ADLs. During observed tracheostomy care, the respiratory therapist removed the tracheostomy dressing, cleansed the area with saline and gauze, and used a closed suction tracheal catheter that had been stored at the bedside in a clear supply bag. The catheter was connected to suction tubing on the bedside table and used to suction the resident’s tracheostomy tube, then returned to the supply bag. The therapist also removed the inner cannula and replaced it using sterile technique. The therapist confirmed the closed system was stored at bedside in a non-sterile, unclosed supply bag and acknowledged the t-piece remained open during storage. The manufacturer’s instructions stated the product was intended for ventilator-dependent patients and warned that non-sterile contents could cause infection. Proper infection control was not followed during meal service for another resident with Alzheimer’s disease, peripheral vascular disease, and chronic kidney disease who required set-up assistance with eating and had moderately impaired cognition. During lunch service, a CNA removed the tray from the cart, placed it in front of the resident, opened the tray lid, and then used bare hands to grab the resident’s bread and butter it. The CNA confirmed she used her bare hands and touched the bread to butter it. Staff also failed to follow transmission-based precautions for two residents on contact precautions. One resident had an order for contact precautions for klebsiella pneumonia, indwelling devices, and wounds; although a contact precaution sign and PPE cart were outside the room, a CNA entered to deliver the lunch tray without donning PPE. Another resident had an order for contact isolation due to VRE, with a contact isolation sign and PPE cart at the room entrance. Observation showed there were no bins or containers inside the room for staff to discard gowns before exiting, and an LPN confirmed there were no bins in the room for that purpose. The facility policy required standard and transmission-based precautions, and CDC guidance stated staff should wear gown and gloves for contact precautions and don PPE upon room entry and properly discard it before exiting.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.