Failure to Provide Ordered Oxygen Care
Summary
The facility failed to ensure that residents who required respiratory care received oxygen therapy consistent with physician orders and the facility’s policy. The policy titled Oxygen Administration required staff to confirm complete physician orders, determine the appropriate oxygen source and equipment, and change oxygen tubing monthly and as needed. The deficiency involved 2 of 4 sampled residents reviewed for respiratory care, R6 and R48, both of whom had diagnoses including COPD and chronic respiratory failure and were ordered to receive oxygen at 3 LPM via nasal cannula, with tubing changes monthly and humidification checked every shift and changed when empty. For R48, the record showed orders for oxygen tubing to be changed monthly and humidification to be checked every shift and changed when empty. The care plan also included oxygen use and CPAP, with interventions to change oxygen tubing monthly and as needed and to check the humidification bottle every shift and change it when empty. However, observations on multiple days showed the oxygen concentrator set at 3 LPM, the tubing without an identification date for when it was last changed, and the humidification bottle not dated. The resident stated staff rarely changed the tubing and rarely changed the humidification bottles, and later stated staff had not changed the tubing or replaced the humidification bottles since she last spoke with the surveyor. For R6, the record showed orders for oxygen at 3 LPM via nasal cannula, tubing to be changed monthly, and humidification to be checked every shift and changed when empty. The care plan identified oxygen dependence and risk for active infection, but it did not include interventions for monthly tubing changes or humidification checks as ordered. Observations on multiple days showed the oxygen concentrator set at 3 LPM, the tubing without an identification date for when it was last changed, and no humidification attached. The resident stated she could not recall the last time staff changed the tubing because it had been so long and stated there was no humidification attached to the concentrator. Staff interviews indicated nursing staff were responsible for assessing oxygen tubing, humidification, and rate, and the Administrator stated tubing and humidification should be labeled with the date of change and checked every shift.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.