Oxygen Orders, Care Plans, and Equipment Dating Not Maintained
Summary
The facility failed to ensure a current physician order for oxygen for Resident #10, who was admitted with diagnoses including obstructive and reflux uropathy and acute and chronic respiratory failure with hypoxia. The resident’s MDS indicated severe cognitive impairment and substantial maximal assistance with personal hygiene. Although a physician order dated 01/05/26 documented oxygen at 2 liters per minute via nasal cannula every shift for shortness of breath, that order was later discontinued on 01/27/26. A pulmonary consultation dated 02/06/26 documented scattered rhonchi and wheezing, diminished breath sounds on the right, and a plan to initiate immediate oxygen therapy to maintain SpO2 greater than 92%. Nursing documentation showed oxygen administration by staff on multiple dates in late February and early March, but the resident’s nursing care plan did not include documentation for respiratory care and oxygen therapy. During observations, Resident #10’s oxygen concentrator was on and making a very loud sound, the bubble indicator showed 1.5 liters per minute, the long oxygen tubing was undated, and the nasal cannula was not on the resident’s nares. Staff interviews indicated that oxygen therapy requires a physician order, that tubing, cannula, and mask are changed according to the physician order, and that a nursing care plan is needed for oxygen therapy and nebulizing treatment. The facility also failed to ensure oxygen tubing, nasal cannula, and mask were dated for Resident #35, who had diagnoses including prostate cancer, respiratory failure, and diastolic congestive heart failure. The resident’s MDS indicated severe cognitive impairment and dependence for toileting. Physician orders included oxygen via nasal cannula at 2 liters continuously for shortness of breath and an order to change tubing, mask, and/or nasal cannula weekly and as needed. Review of MAR/TAR documentation showed missed weekly changes in early and mid-February, and observations found the oxygen concentrator turned off, tubing stored in a plastic bag with dates written on it, and nebulizing equipment with tubing and mask inside a plastic bag that were not dated. Staff stated that treatment documentation was done electronically and that the date of tubing and mask changes should be documented on the plastic bag.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.