F0908 F908: Keep all essential equipment working safely.
D

Equipment Maintenance Failure

Shadelands Post AcuteWalnut Creek, California Survey Completed on 05-14-2026

Summary

The facility failed to ensure essential equipment was properly maintained when Resident 34's bed made a loud cranking noise as it was moved up and down during care. During a concurrent observation and interview, Resident 34 was seen with a healed wound on the buttock while the bed was operated with the remote, and the bed produced the loud noise. Resident 34 stated he could live with the noise. Staff interviews showed the noise was known to nursing staff and maintenance. A CNA stated the bed made loud noise from time to time and that maintenance had been notified. An RN stated the bed was sometimes lubricated. The Maintenance Supervisor stated he was aware of the cranking noise, that about half of the resident beds in the facility made cranking noise, and that beds were oiled when residents were discharged because of concern about the smell of lubricant. He also stated the facility had a plan to replace beds that made loud noise when used. The Administrator stated the facility was in the process of buying new beds and planned to replace all residents' beds. The facility policy on Preventative Maintenance stated the facility shall maintain a preventative maintenance program designed to minimize equipment failure, maintain resident safety and comfort, reduce operational disruptions, and ensure compliance with regulatory requirements.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0908 citations
Inoperable Commercial Washer in Laundry Department
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

In the laundry department, 1 of 2 commercial washers was out of service for more than 8 months, leaving only 1 washer available for resident laundry. Laundry Aides stated they used the working washer for all residents and that keeping up with timely laundry services was sometimes challenging with only 1 machine.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Hoyer Lift Batteries Not Maintained in Safe Operating Condition
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

A resident who required a mechanical lift for transfers experienced repeated Hoyer lift battery failures during transfers, including one observed transfer where the lift stopped working while he was being lowered. Staff reported that lift batteries were often not charged, that overnight staff were responsible for charging them, and that they sometimes used the emergency release to lower the resident when the battery died. The DON and other staff confirmed the batteries were not consistently checked or maintained, and the maintenance supervisor said batteries were only replaced occasionally.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Flooring Renovation Started Before Construction Review Approval
E
F0908 F908: Keep all essential equipment working safely.
Short Summary

Flooring Renovation Started Before Construction Review Approval: The facility removed carpet and installed laminate flooring in resident areas before receiving DOH Construction Review Services approval. The Administrator said the second-floor west unit remodeling had already been completed and residents were moved to another unit during the work. Notices to residents described planned flooring replacement, observation confirmed new wood flooring in the hallway and resident rooms, and a resident said they were relocated for at least two weeks. The Regional Plant Operations Director stated the approval was still pending and that they were unsure of the approval process.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Laundry Equipment Not Maintained in Safe Operating Condition
E
F0908 F908: Keep all essential equipment working safely.
Short Summary

Laundry equipment was not maintained in safe operating condition. A resident with ESRD on dialysis reported that clothes came back stinking, while the Laundry Supervisor said the industrial washer kept breaking down, hot water was not getting hot, the wrong soap was being used for resident clothing, and the department lacked a hopper for washing soiled linens. Observation showed a small washer overfilled with sheets, and staff gave mixed reports about washer breakdowns and linen shortages.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Mechanical Lift Found With Exposed Charging Cord
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

Mechanical lift equipment on the 3rd floor was observed with exposed black and red inner cords from the grey charging cord hanging out. An RN said the lift should not be used if the cords are exposed, and the DON stated such equipment should be reported to maintenance and removed from the floor for safety precautions. The Maintenance Director confirmed the outer grey cord protects the inner cords, and the maintenance log showed no repair report for the lift.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Expired Ambu Bags Found on Two Crash Carts
E
F0908 F908: Keep all essential equipment working safely.
Short Summary

Expired Ambu Bags Found on Two Crash Carts: The facility failed to ensure two crash carts were in safe operating condition when an Ambu bag on the First Floor Crash Cart and an Ambu bag on the Second Floor Crash Cart were both found expired. RN staff confirmed the expired equipment and acknowledged the carts were not maintained as required by the facility's crash cart management process.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments