F0908 F908: Keep all essential equipment working safely.
D

Kitchen Stove Burner Not Functioning

Spindletop Hill Nursing And Rehabilitation CenterBeaumont, Texas Survey Completed on 08-05-2026

Summary

The facility failed to maintain essential kitchen equipment in safe operating condition when the back center burner on the gas stove did not ignite when the knob was turned. During an observation and interview, the burner was checked and found not to light, and staff reported it had not been lighting for about 1 to 2 months. No gas odors or hissing sounds were observed in the kitchen, and the burner was later taken out of service until repaired. Staff interviews showed that cooks were expected to notify the DM when equipment was not working properly, and the DM was expected to notify the Maintenance Director and enter the concern into the electronic Maintenance reporting system. The Regional Director of Dietary Services stated the issue may have involved miscommunication between dietary and maintenance departments and said all dietary staff were educated to notify the DM with any equipment not working properly. The DM stated she had worked on the stove previously and thought the pilot light had gone out, while the Maintenance Director said he was not aware of the problem until it was brought to his attention. On a later observation, the same back middle burner still did not light immediately. A cook stated she was unsure whether water from eggs may have put out the pilot and said she had last seen it working a few days earlier. The Administrator stated he had only just been made aware that the stove had a burner not working, and the Maintenance Director had checked it and ordered a part to repair it. Record review also showed kitchen rounds documentation indicating the stove and oven were clean and equipment well maintained, along with facility policy stating that all staff should utilize the electronic Maintenance reporting system and that equipment repairs must be documented with a work order associated with the asset.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0908 citations
Expired Supplies Found in Crash Carts
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

Expired supplies were found in two crash carts on nursing units 1B and 2B. An opened Ambu bag in the 2B cart was expired, and the 1B cart contained two expired Ambu bags and expired Assure Prism glucometer strips. RN staff confirmed the items were expired and should not have been in the carts.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Elevator Malfunctioned and Remained in Need of Repair
E
F0908 F908: Keep all essential equipment working safely.
Short Summary

The facility failed to keep one of its elevators in safe operating condition. Records showed elevator two malfunctioned multiple times and needed a replacement part, and residents and staff were aware of the repeated malfunctions. The Administrator confirmed the elevator was malfunctioning and needed repair.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Dryer Lint Traps
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

Failure to Maintain Dryer Lint Traps: Surveyors observed heavy lint buildup in both dryer lint traps, with lint hanging from each trap and covering the full trap surface. The sign-off log showed no entries after the prior shift, and staff interviews confirmed the required two-hour checks and documentation were not consistently completed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Glucometer Calibration and Quality Control Not Documented
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

Glucometer calibration and QC were not documented for one glucometer on Medication Cart D, and the QC log was blank for the scheduled check. LVN and DON verified that the 11-7 shift was responsible for nightly/daily calibration and QC to support accurate blood sugar readings.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Thermostats Not Powered On or Working
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

Thermostats Not Powered On or Working: Two of five sampled thermostats were observed turned off with black screens and no visible power. A resident’s RP said it was always hot in the resident’s room and a fan was provided because there was no working AC. The MS stated the thermostats should be on and working to regulate room temperatures, but he was unsure how often they should be checked.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Broken Electrical Outlet Near Kitchen Oven
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

Broken Electrical Outlet Near Kitchen Oven: An outlet near the kitchen oven had a broken cover with visible live wires and components. Staff said it had been broken for a week or two and was verbally reported, but no work order was entered in the maintenance system. The MDS stated the issue was only verbally relayed to maintenance, and the FSD said it was not reported through the electronic maintenance program.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Texas

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Texas — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.