F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
D

IV insertion site and date label were covered with tape

Canyon Oaks Nursing And Rehabilitation CenterCanoga Park, California Survey Completed on 05-07-2026

Summary

The facility failed to ensure the IV insertion site and the label indicating the date of insertion were visible and not covered with white tape for one resident who was admitted with diagnoses including UTI, bacteremia, and dementia. The resident’s H&P indicated he did not have the capacity to make his own medical decisions, and his MDS showed he required substantial assistance with activities such as eating. His care plan for IV therapy complications, initiated after admission, directed staff to monitor and document signs and symptoms of infection and leaking at the IV site, and the active order summary directed staff to monitor the IV site every shift for signs and symptoms of complications. During observation, the resident was seen sitting in his wheelchair with white tape wrapped around his left AC area. When the RN examined the arm, she stated the white tape was covering the IV insertion site and that the site and insertion-date label could not be observed because they were covered. She stated she could not fully implement the order to monitor the IV site because it was not visible and complications could have been missed, and she could not verify when the IV had been inserted because the date label was covered. The DON stated the IV insertion site must be visible to monitor for complications and that nurses should not have added that much white tape; if the dressing was loose, it should have been reinforced or changed instead.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0694 citations
Failure to Include PICC Line Care and Management
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Failure to Include PICC Line Care and Management: A resident with pneumonitis, stroke, and hemiplegia had a PICC line observed in the L upper arm, but the admission orders and care plan did not include PICC line care and management. Facility policy required a prescriber order with specific flushing/locking details and documentation of the procedure, and an RN later confirmed the omission.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Obtain IV Therapy and Flush Orders
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Failure to obtain physician orders for IV therapy and flush orders affected two residents. One resident had a midline IV for osteomyelitis and was receiving Meropenem, but there was no documented flush order or evidence the line was flushed before and after med administration. Another resident had an IV heparin lock in the forearm, but the MAR showed no physician order for IV therapy and no flush orders; the DON confirmed the orders should have been obtained.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Wrong enteral feeding formula given to two residents
E
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Wrong enteral feeding formula was given to two residents with feeding tubes. One resident with diabetes mellitus and respiratory failure was ordered Nutren 2.0, and another resident with respiratory failure and dysphagia was ordered Isosource 1.5, but staff switched the formulas and administered them to the wrong residents. Interviews confirmed the error, and staff stated LPNs were responsible for checking the physician order and giving enteral feeds one resident at a time.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain IV Flush Orders for a Resident with a Peripheral IV
E
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with dementia, DM2, and chronic venous insufficiency had a PIV and IV medication orders, but the IV flush orders were discontinued while the catheter remained in place. The MAR and order summary showed no current flush orders, and an LPN stated he did not flush the IV because there were no physician orders. The DON verified the flush orders were discontinued and said the IV should have been discontinued at the same time.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
IV Fluids Not Initiated and Monitored per Order
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident receiving IV NS for dehydration had gaps in IV initiation, flush orders, and site monitoring. An RN observed blood in the tubing, flushed the line without cleaning the port, and replaced the bag and tubing, while the record showed missing documentation for IV initiation/discontinuation, no flush or dressing-change orders, and no documented insertion-site assessments during continuous infusion.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Line Dressing Not Changed Within Required Interval
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

PICC Line Dressing Not Changed Within Required Interval: A resident with a PICC line, severe sepsis, and septicemia had an IV dressing on the right arm that remained dated beyond the expected 7-day change interval while receiving IV vancomycin. The resident was unsure how often the dressing should be changed, and both an LVN and the DON stated PICC dressings are expected to be changed every 7 days or as needed if soiled.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.