AED Not Maintained in Ready-to-Use Condition
Summary
The facility failed to maintain a working automated external defibrillator (AED) for emergency CPR use. During an observation, the only AED available in the facility was located outside the nurse’s station in a wall holder, intermittently beeping, with the electrode pads not attached and a red X indicator light showing that it was not in safe operating condition. The DON later removed the AED from its case and confirmed that the pads were not attached and that the device was beeping. The DON stated that the night nurses, LVN H and LVN J, were responsible for conducting readiness checks and documenting them, including checking for expired pads and whether the machine was functioning properly. She said she was not aware the AED was not ready for use. The Administrator also stated she had not noticed the missing electrodes, the beeping, or the red X indicator, and said the nighttime nurses were responsible for checking and documenting the AED each night. The DON and Administrator both indicated that CPR included use of the AED, and the DON said the nurses had been trained on AED use, although the training used a different AED than the one the facility had on hand. Record review showed the old crash cart checklist only had a check mark for AED #1 and did not indicate whether a red X or green check mark was present, whether electrodes were attached, or whether the unit was beeping. A revised form later included fields for daily date, green check visible, no red X, pads present, battery ok, no beeping, issues, and staff initials. The facility’s policy stated that AED equipment was available for emergency use and that the DON or designee would test and document the AED’s operating status according to the manufacturer’s guidelines. The manufacturer’s manual stated the unit should not be used if it displayed a red X or emitted a beeping tone and that the electrode cable should remain connected at all times. Record review also showed the facility had not tested the AED according to the manufacturer’s guidelines for 23 days.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.