F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
D

Midline Dressing Not Maintained per Order and Policy

Hampton Ridge Healthcare And RehabilitationToms River, New Jersey Survey Completed on 03-12-2026

Summary

The facility failed to ensure that a midline dressing was changed and maintained in accordance with professional standards of practice and facility policy for Resident #101, who had an order for a midline/PICC IV dressing, extension set, and cap to be changed 24 hours after insertion and then every week and as needed. The resident also had an order for a midline to provide IV fluids for acute kidney injury, and the care plan identified a focus for potential complications related to IV access site, IV therapy due to antibiotic treatment and hydration. The resident’s quarterly MDS indicated cognitive intactness with a brief interview for mental status score of 15/15. On observation, the surveyor saw the resident in bed with a midline catheter in the right arm and a translucent adhesive dressing over the insertion site that was handwritten with the date 3/2. During interview, the resident stated that no one had changed the midline dressing since then. Later the same day, the surveyor observed that the old dressing had been removed and a new dressing dated 3/11/26 was applied. The DON showed the surveyor the removed dressing, which had been recovered from a trash can, and stated that the new dressing had been applied that day. The facility policy titled Catheter Insertion and Care stated that midline catheter dressings are to be changed 24 hours after insertion, every 5-7 days, or if wet, dirty, not intact, or compromised.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0694 citations
Failure to Include PICC Line Care and Management
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Failure to Include PICC Line Care and Management: A resident with pneumonitis, stroke, and hemiplegia had a PICC line observed in the L upper arm, but the admission orders and care plan did not include PICC line care and management. Facility policy required a prescriber order with specific flushing/locking details and documentation of the procedure, and an RN later confirmed the omission.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Obtain IV Therapy and Flush Orders
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Failure to obtain physician orders for IV therapy and flush orders affected two residents. One resident had a midline IV for osteomyelitis and was receiving Meropenem, but there was no documented flush order or evidence the line was flushed before and after med administration. Another resident had an IV heparin lock in the forearm, but the MAR showed no physician order for IV therapy and no flush orders; the DON confirmed the orders should have been obtained.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Wrong enteral feeding formula given to two residents
E
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Wrong enteral feeding formula was given to two residents with feeding tubes. One resident with diabetes mellitus and respiratory failure was ordered Nutren 2.0, and another resident with respiratory failure and dysphagia was ordered Isosource 1.5, but staff switched the formulas and administered them to the wrong residents. Interviews confirmed the error, and staff stated LPNs were responsible for checking the physician order and giving enteral feeds one resident at a time.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain IV Flush Orders for a Resident with a Peripheral IV
E
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with dementia, DM2, and chronic venous insufficiency had a PIV and IV medication orders, but the IV flush orders were discontinued while the catheter remained in place. The MAR and order summary showed no current flush orders, and an LPN stated he did not flush the IV because there were no physician orders. The DON verified the flush orders were discontinued and said the IV should have been discontinued at the same time.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
IV Fluids Not Initiated and Monitored per Order
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident receiving IV NS for dehydration had gaps in IV initiation, flush orders, and site monitoring. An RN observed blood in the tubing, flushed the line without cleaning the port, and replaced the bag and tubing, while the record showed missing documentation for IV initiation/discontinuation, no flush or dressing-change orders, and no documented insertion-site assessments during continuous infusion.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Line Dressing Not Changed Within Required Interval
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

PICC Line Dressing Not Changed Within Required Interval: A resident with a PICC line, severe sepsis, and septicemia had an IV dressing on the right arm that remained dated beyond the expected 7-day change interval while receiving IV vancomycin. The resident was unsure how often the dressing should be changed, and both an LVN and the DON stated PICC dressings are expected to be changed every 7 days or as needed if soiled.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across New Jersey

Get a heads-up on the newest immediate-jeopardy (J–L) citations in New Jersey — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.