F0880 F880: Provide and implement an infection prevention and control program.
E

Failure to Implement Effective Infection Prevention and Control Practices

The Pavilion At KentonCovington, Kentucky Survey Completed on 03-26-2026

Summary

The deficiency involves the facility’s failure to establish and maintain an effective infection prevention and control program, as evidenced by multiple observations of noncompliance with policies, CDC guidance, and basic infection control practices. Surveyors observed that residents on Enhanced Barrier Precautions (EBP) did not have required signage posted on their room doors, despite care plans and orders indicating the need for EBP. Residents with devices such as a PEG tube, colostomy, dialysis catheter, and indwelling urinary catheter were under EBP, but their rooms lacked appropriate signage. Staff interviews confirmed that EBP should have been initiated and care planned upon admission for these residents and that signage should have been posted, but this was not done or was delayed. The deficiency also includes improper management of enteral nutrition systems for several residents receiving tube feedings. Surveyors observed tube feeding bottles and tubing hanging on poles without dates or times indicating when they were opened or hung, and with tubing primed but without protective end caps when not in use. Staff, including LPNs and the PA, acknowledged that tube feedings should be dated and timed, that they are only good for a limited period once hung, and that the absence of end caps could allow germs or bacteria to be introduced into the feeding system. The DON and Administrator stated their expectations that tube feedings be dated, timed, and capped, and that undated or uncapped systems should be replaced, but the observed practice did not align with these expectations. Additional deficiencies were identified in the cleaning and disinfection of shared equipment and surfaces between resident use. A nurse performing blood glucose checks placed used supplies and a glucometer on the medication cart surface, cleaned the glucometer, but did not disinfect the cart surface before preparing supplies for another resident on the same surface. Another nurse used a blood pressure cuff on two different residents without cleaning it between uses, stating she normally would use disinfectant wipes but forgot and did not have wipes in her cart. In a separate incident, staff used a mechanical lift to transfer a resident back to bed and then placed the lift in the hallway without cleaning it after use. Staff and leadership interviews confirmed that shared equipment and surfaces should be disinfected between residents to prevent cross-contamination, but this was not consistently done. Collectively, these observations show that the facility did not follow its own infection prevention and control policies related to EBP implementation and signage, safe handling of tube feedings, and cleaning and disinfection of shared equipment and surfaces. The facility’s policies required surveillance of staff adherence to infection control practices, proper use of standard precautions, and cleaning and reprocessing of reusable equipment between residents, but surveyors found repeated instances where these requirements were not met for multiple sampled residents.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Use EBP, Perform Hand Hygiene, and Maintain Sanitary Laundry Practices
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with an indwelling Foley catheter had EBP identified in the care plan, but staff did not consistently wear gowns during close contact care, including vital signs, medication administration, hygiene-related contact, and topical treatment. In addition, a TMA administered medications to three residents without sanitizing hands between residents or before handling medications, despite policy and DON expectations requiring hand hygiene. Laundry practices were also inconsistent with sanitary handling, as staff sorted soiled laundry without gowns and gloves being available in the room and reported using only gloves for most dirty laundry tasks.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses During Insulin Administration
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An LVN failed to follow hand hygiene and insulin pen preparation practices during a medication pass for a resident with diabetes. After washing his hands, he turned off the faucet with his bare hand, then administered insulin without cleaning the insulin pen’s rubber seal with alcohol first. The DON stated both actions were a break in infection control, and the facility policy required proper hand hygiene and noted that gloves do not replace hand hygiene.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Perform Hand Hygiene During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to perform hand hygiene during wound care was identified for a resident with a stage 4 coccyx pressure ulcer, diabetes, CAD, and HTN. An RN and the ADON provided perineal and wound care, but the RN repeatedly changed gloves without sanitizing hands and did not sanitize hands or change gloves before removing soiled packing and applying new wound packing and a dressing. The DON stated staff were expected to sanitize hands every time gloves were removed, and facility policy required hand hygiene after glove removal and before moving from a contaminated body site to a clean body site.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Medication Pass and Respiratory Equipment Storage
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An RN failed to follow hand hygiene and safe medication handling during med pass, including touching dropped tablets and handling meds without gloves or hand hygiene between steps. The facility also failed to store nebulizer mouthpieces and masks in labeled bags when not in use for residents receiving respiratory treatments, including a resident with CHF, CKD, DM2, and anemia. The DON confirmed the expected storage and handling practices were not followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Cleaning of Community-Use Glucometer
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An LPN was observed cleaning a community-use glucometer with an alcohol pad instead of the bleach wipe or equivalent required by the facility policy. The LPN stated he always used alcohol pads, while the DNS stated staff were to use bleach wipes. The glucometer was used for CBG checks on several residents with diabetes, and their records did not indicate a BBP.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use PPE During Wound Care and Replace Oxygen Tubing Timely
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with MRSA and an abdominal wound was observed during wound care with contracted wound care staff entering without proper PPE, touching room items, and performing wound care without consistent hand hygiene or glove changes while moving from dirty to clean tasks; the same staff then went to another resident’s room without gowns despite EBP signage. The facility also failed to timely replace another resident’s oxygen tubing for CPAP/oxygen use, and the tubing had no label showing when it was last changed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Kentucky

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Kentucky — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.