Failure to Implement and Follow Enhanced Barrier Precautions During Wound Care
Summary
Surveyors identified a deficiency in the facility’s infection prevention and control program related to improper use and implementation of Enhanced Barrier Precautions (EBP) during wound care. One resident with an indwelling urinary catheter had an active order and care plan for EBP, and a door sign specifying that gown and gloves were required for high-contact resident care activities, including wound care and device care. During an observation, an RN and a CNA entered this resident’s room, performed hand hygiene, donned gown and gloves, and completed catheter care in accordance with the posted EBP instructions. However, after completing catheter care, the RN instructed the CNA that they could remove their gowns because EBP was “only for the catheter,” and both staff removed their gowns and gloves, performed hand hygiene, and then donned only clean gloves to perform a dressing change on the resident’s right heel and pinky toe, despite the door sign indicating gown and gloves were required for wound care. A second resident had multiple open wounds on both lower extremities that required cleansing, application of collagen with wound gel and alginate, and coverage with border gauze dressings. Progress notes documented that these wounds originated as skin tears and were slowly healing, and active wound care orders were in place. During an observation of wound care for this resident, an RN and a nurse aide performed hand hygiene and donned gloves but did not wear gowns. There was no EBP sign or PPE set up outside the room, and there was no order for EBP in the electronic medical record, even though the resident had open wounds requiring dressing changes. In interviews, the RN stated that EBP was required for chronic wounds such as pressure, venous, and arterial wounds, and that EBP for the first resident applied only to catheter care. The CNA reported that she relied on the door sign and believed she only needed to gown for catheter care, brief care, or toileting, and not for transferring if she was not in contact with the catheter. The Infection Preventionist explained that EBP was used for chronic wounds and indwelling devices and stated that staff would only need to gown when providing care to the Foley catheter, while the DON stated that EBP was for residents with devices or dressing changes to prevent MDROs and that staff should wear gown and gloves even when not providing direct catheter care. The facility’s written EBP policy specified that EBP applies to residents with chronic wounds and/or indwelling medical devices and that PPE for EBP is necessary when performing high-contact care activities, including wound care and medical device care, which was not consistently followed in the observed wound care encounters.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.