F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
D

Improper PICC Line Dressing Care and BP Taken Over PICC Line

Ruleme CenterEustis, Florida Survey Completed on 01-23-2026

Summary

Provide for the safe, appropriate administration of IV fluids when needed was not met for Resident #39, who had a PICC line in the right upper arm. During observation, the resident was lying in bed in a hospital gown with the PICC line dressing dated 1/19/2026, and a gauze pad was seen under the transparent dressing. The physician order for the PICC line required the dressing to be changed within 24 hours of admission, insertion, or reinsertion and every 7 days thereafter using sterile technique, with arm circumference and external catheter length measured. The resident was observed again the next day with the same PICC line dressing dated 1/19/2026 and a gauze pad still under the transparent dressing. Staff B, an LPN, then obtained a blood pressure reading on the resident’s right upper arm directly over the PICC line. Staff C, an LPN Unit Manager, stated that she would not use gauze for a central line dressing change, although gauze pads came in the central line dressing kits. The DON stated that the standard of care was to change a central IV line dressing every 72 hours if gauze was under the transparent dressing and that staff were not to take blood pressure on the arm with a PICC line. Staff B later stated she was aware it was not standard of care to take a blood pressure reading over a PICC line.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0694 citations
IV access and medication labeling deficiencies
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

IV access and medication labeling deficiencies: A resident with a PICC line had no documented admission measurement of external catheter length or arm circumference, another resident’s IV tubing was observed without the required date, time, and RN initials, and a third resident’s meropenem IV bag was not labeled with the date, time, and initials. Facility policy required labeling of IV solutions and documentation of PICC measurements.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Document Baseline Midline IV Measurements
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Failure to Document Baseline Midline IV Measurements: A resident receiving IV antibiotics via a midline IV had no documented baseline external catheter length or arm circumference measurements when admitted from the acute hospital. The resident’s care plan did not address the midline IV, and the IV MAR lacked baseline documentation. RN confirmed staff performed dressing changes and measurements, but could not verify any baseline values from the acute care hospital; the DON verified the findings.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Dressing Not Changed as Ordered
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with a PICC line, diabetes, obesity, atrial fibrillation, and CHF had no documented PICC-related care plan interventions, and the PICC dressing was found stained, loosening, and dated well beyond the weekly change schedule. Although the MAR showed the dressing change as completed, staff interviews confirmed it was overdue and should have been changed sooner, with the DON acknowledging it was late and that loose or soiled dressings require more frequent attention.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Flush IV Catheter During Antibiotic Administration
E
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident received IV Cefepime multiple times through a long-term IV catheter, but the MAR lacked documentation that the catheter was flushed before and after administration as required by facility policy. The DON confirmed the nurse should have flushed the IV catheter pre- and post-medication administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Line Measurements Not Documented
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident receiving IV antibiotics through a PICC had no documented baseline or weekly catheter length and arm circumference measurements, despite an order for the RN to record them after each Sunday dressing change. RNs stated the measurements were needed to confirm the catheter remained in position, but the IV MAR showed only dressing changes and no measurements. The DON confirmed the record lacked both admission and weekly measurements, and the complaint noted the catheter had moved, leading to a hospital return, PICC removal, and replacement catheter placement.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Line Removal Not Timely or Fully Documented
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

PICC Line Removal Not Timely or Fully Documented: A resident with severe cognitive impairment, dependence for all ADLs, and IV antibiotic therapy had a PICC line that was not removed when the antibiotic ended, and nursing documentation showed conflicting removal entries. The chart lacked a physician order for removal, lacked confirmation that the full line including the tip was removed, and lacked documentation of post-removal site inspection or monitoring for complications.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Florida

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Florida — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙