Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0311
E

Failure to Maintain Vertical Opening Enclosures

Pittsburgh, Pennsylvania Survey Completed on 02-06-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain proper vertical opening enclosures, as evidenced by an observation on February 6, 2025. During the inspection, it was noted that floors five and seven, which were unoccupied at the time, had multiple unsealed openings in a bathroom pipe chase wall. These openings were present due to ongoing work to replace a leaking drain pipe. This deficiency affected two out of twelve smoke compartments in the facility. The issue was confirmed through an interview with the Facility Administrator and Maintenance Director on the same day.

Plan Of Correction

Unsealed openings on floors 5 and 7 will be repaired by 3/21/2025. House audit will be completed by Maintenance Director or designee on unsealed openings. The administrator or designee will reeducate Maintenance Director on unsealed openings - K311. Identified rooms will be inspected for new openings monthly by the Maintenance Director or designee. Findings will be reported to Quality Assurance and Performance Improvement committee meetings.