Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0131
F

Deficient Fire Separation in Facility Occupancies

Edison, New Jersey Survey Completed on 12-20-2024

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to ensure that sections of health care facilities classified as other occupancies were properly separated from areas of healthcare occupancies by construction with a two-hour fire resistance rating. This deficiency was identified during observations and interviews conducted on December 19, 2024. Specifically, the separation between the Healthcare occupancy and the Residential occupancy was compromised by a 1.5-inch and 2.5-inch unprotected penetration for wire pass-throughs. Additionally, a 2-inch-high by 48-inch-wide section of brick was missing above the fire-rated door assembly between the two occupancies. These observations were confirmed by the USTFOTAT at the time of the inspection. The facility's representative was informed of these deficient practices during the Life Safety Code exit conference on December 20, 2024.

Plan Of Correction

1/9/25 1. All residents have the potential to be affected by this deficient Life Safety Code. The maintenance department repaired the 2 unprotected penetrations for the pass-through of wires on 1/8/25 using UL listed NUEX Order 26.4(DX LC 150 fire-stop sealant. The maintenance department repaired the 2 inch by 48 inch wide section of brick missing above the fire rated door assembly between the two occupancies on 1/8/25 using intumescent fire-stop pillows and UL listed NJ Ex Order 26.4(15) LC 150 fire-stop sealant. 2. The facility's maintenance schedule will be revised by the Director of Maintenance to include a monthly inspection of fire-rated assemblies between the healthcare occupancy and the residential occupancy to confirm that the two hour fire resistance rating is intact with no penetrations using an audit tool. 3. The Director of Maintenance will review the fire rated assembly inspection reports monthly ongoing and report the results to the administrator and to the QAPI committee monthly for 6 months.