F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
D

Failure in Midline Catheter Care and Monitoring

Mason Creek Transitional Care Of KatyKaty, Texas Survey Completed on 12-12-2024

Summary

The facility failed to ensure the safe and appropriate administration of intravenous (IV) fluids for a resident, specifically in the care and monitoring of a midline catheter. The resident, an elderly female with multiple diagnoses including stage 4 pressure ulcer, dementia, and osteomyelitis, was receiving Piperacillin-Tazobactam via a midline catheter. However, there were no physician orders or care plans addressing the care and monitoring of the midline catheter, nor were there orders for the regular changing of the midline dressing. Observations revealed that the midline dressing was not changed according to the facility's policy, which required changes every 7 days. During a dressing change, a Licensed Vocational Nurse (LVN) did not follow proper aseptic technique, failing to clean the site with alcohol before using betadine, and did not clean in the correct circular motion. The LVN was unaware of the correct procedure and had not received recent training on midline dressing changes. Interviews with facility staff, including the Director of Nursing (DON) and the Nurse Practitioner (NP), indicated a lack of communication and oversight in updating physician orders and care plans. The NP admitted to possibly entering the order incorrectly, and the DON acknowledged that the necessary orders for monitoring and care were not in the system, leading to the care plan not being updated. This oversight placed the resident at risk of infection due to improper midline care and monitoring.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0694 citations
IV access and medication labeling deficiencies
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

IV access and medication labeling deficiencies: A resident with a PICC line had no documented admission measurement of external catheter length or arm circumference, another resident’s IV tubing was observed without the required date, time, and RN initials, and a third resident’s meropenem IV bag was not labeled with the date, time, and initials. Facility policy required labeling of IV solutions and documentation of PICC measurements.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Document Baseline Midline IV Measurements
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Failure to Document Baseline Midline IV Measurements: A resident receiving IV antibiotics via a midline IV had no documented baseline external catheter length or arm circumference measurements when admitted from the acute hospital. The resident’s care plan did not address the midline IV, and the IV MAR lacked baseline documentation. RN confirmed staff performed dressing changes and measurements, but could not verify any baseline values from the acute care hospital; the DON verified the findings.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Dressing Not Changed as Ordered
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with a PICC line, diabetes, obesity, atrial fibrillation, and CHF had no documented PICC-related care plan interventions, and the PICC dressing was found stained, loosening, and dated well beyond the weekly change schedule. Although the MAR showed the dressing change as completed, staff interviews confirmed it was overdue and should have been changed sooner, with the DON acknowledging it was late and that loose or soiled dressings require more frequent attention.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Flush IV Catheter During Antibiotic Administration
E
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident received IV Cefepime multiple times through a long-term IV catheter, but the MAR lacked documentation that the catheter was flushed before and after administration as required by facility policy. The DON confirmed the nurse should have flushed the IV catheter pre- and post-medication administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Line Measurements Not Documented
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident receiving IV antibiotics through a PICC had no documented baseline or weekly catheter length and arm circumference measurements, despite an order for the RN to record them after each Sunday dressing change. RNs stated the measurements were needed to confirm the catheter remained in position, but the IV MAR showed only dressing changes and no measurements. The DON confirmed the record lacked both admission and weekly measurements, and the complaint noted the catheter had moved, leading to a hospital return, PICC removal, and replacement catheter placement.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Line Removal Not Timely or Fully Documented
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

PICC Line Removal Not Timely or Fully Documented: A resident with severe cognitive impairment, dependence for all ADLs, and IV antibiotic therapy had a PICC line that was not removed when the antibiotic ended, and nursing documentation showed conflicting removal entries. The chart lacked a physician order for removal, lacked confirmation that the full line including the tip was removed, and lacked documentation of post-removal site inspection or monitoring for complications.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Texas

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Texas — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙