F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
J

Failure to Maintain Central Venous Line Leads to Infection

Cornerstone Retirement CommunityTexarkana, Texas Survey Completed on 11-06-2024

Summary

The facility failed to maintain a central venous line site according to professional standards for a resident, leading to a missed dressing change. The resident, a male with a history of urinary tract infection, pneumonia, and a carrier of carbapenem-resistant Enterobacterales, was observed with a midline catheter dressing that had not been changed since the date of insertion. This oversight resulted in the resident developing a localized infection at the site, which was confirmed by a Nurse Practitioner. The resident's medical records did not show documentation of a central venous line dressing change or site assessment for several days. During observations, the dressing was noted to be dated from the time of hospital discharge, and the site was red and warm to the touch. The resident was subsequently sent to the hospital for the replacement of the midline catheter due to the infection. Interviews with facility staff revealed that the admitting nurse failed to input an order for dressing changes, which contributed to the oversight. The Director of Nursing and other staff acknowledged that the dressing should have been changed every seven days and documented accordingly. The lack of a physician's order for central venous line care and the failure to follow the facility's protocol for dressing changes were identified as key factors leading to the deficiency.

Penalty

Inspection fine: $39,764
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0694 citations
IV access and medication labeling deficiencies
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

IV access and medication labeling deficiencies: A resident with a PICC line had no documented admission measurement of external catheter length or arm circumference, another resident’s IV tubing was observed without the required date, time, and RN initials, and a third resident’s meropenem IV bag was not labeled with the date, time, and initials. Facility policy required labeling of IV solutions and documentation of PICC measurements.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Document Baseline Midline IV Measurements
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Failure to Document Baseline Midline IV Measurements: A resident receiving IV antibiotics via a midline IV had no documented baseline external catheter length or arm circumference measurements when admitted from the acute hospital. The resident’s care plan did not address the midline IV, and the IV MAR lacked baseline documentation. RN confirmed staff performed dressing changes and measurements, but could not verify any baseline values from the acute care hospital; the DON verified the findings.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Dressing Not Changed as Ordered
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with a PICC line, diabetes, obesity, atrial fibrillation, and CHF had no documented PICC-related care plan interventions, and the PICC dressing was found stained, loosening, and dated well beyond the weekly change schedule. Although the MAR showed the dressing change as completed, staff interviews confirmed it was overdue and should have been changed sooner, with the DON acknowledging it was late and that loose or soiled dressings require more frequent attention.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Flush IV Catheter During Antibiotic Administration
E
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident received IV Cefepime multiple times through a long-term IV catheter, but the MAR lacked documentation that the catheter was flushed before and after administration as required by facility policy. The DON confirmed the nurse should have flushed the IV catheter pre- and post-medication administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Line Measurements Not Documented
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident receiving IV antibiotics through a PICC had no documented baseline or weekly catheter length and arm circumference measurements, despite an order for the RN to record them after each Sunday dressing change. RNs stated the measurements were needed to confirm the catheter remained in position, but the IV MAR showed only dressing changes and no measurements. The DON confirmed the record lacked both admission and weekly measurements, and the complaint noted the catheter had moved, leading to a hospital return, PICC removal, and replacement catheter placement.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Line Removal Not Timely or Fully Documented
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

PICC Line Removal Not Timely or Fully Documented: A resident with severe cognitive impairment, dependence for all ADLs, and IV antibiotic therapy had a PICC line that was not removed when the antibiotic ended, and nursing documentation showed conflicting removal entries. The chart lacked a physician order for removal, lacked confirmation that the full line including the tip was removed, and lacked documentation of post-removal site inspection or monitoring for complications.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Texas

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Texas — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙