F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
E

Deficiencies in IV Therapy Management

Aristacare At East FallsPhiladelphia, Pennsylvania Survey Completed on 10-04-2024

Summary

The facility failed to provide care and assessments consistent with professional standards of practice related to intravenous therapy for three residents. For Resident R43, there was a lack of documentation regarding the care of a PICC line, despite a physician's order for weekly dressing changes. An observation revealed that the PICC line dressing was not dated, and this was confirmed by a licensed nurse. Resident R44 also had issues with the care of their PICC line. The Medication Administration Record showed no documentation of PICC line care, and an observation found the dressing undated. A licensed nurse confirmed these findings during an interview. For Resident R150, the PICC line dressing was dated two weeks prior and was peeling away from the skin. The licensed nurse was unaware of any medications or fluids administered through the PICC line and was unsure of the dressing change frequency. There were no physician orders for the care and maintenance of the PICC line, and no notes related to its removal, despite an order to remove it.

Penalty

Inspection fine: $35,363
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0694 citations
TPN Order Not Transcribed or Documented After Admission
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident was admitted with hospital paperwork indicating a regular diet with TPN and a PICC line, but the facility did not transcribe a TPN order into the chart or document the hospital communication that TPN had been discontinued. Staff relied on verbal clarification from the hospital, while the record lacked clear TPN administration, mixture, and monitoring orders. The resident later required IV fluids and a new PICC line after low BP was noted.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
IV Therapy Not Consistently Documented or Monitored
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

IV Therapy Not Consistently Documented or Monitored: A resident with Parkinson’s Disease and acute respiratory failure had IV fluid and IV antibiotic orders, but the IV site was observed with a loose, unsecured, undated dressing and a dark red dry substance on it. Staff reported the IV was left in place after fluids were given, then restarted for more fluids, but IV insertion, removal, and restart attempts were not documented, and the resident’s chart lacked IV documentation for several days.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unlabeled and undated peripheral IV dressing
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Unlabeled and undated peripheral IV dressing: A resident receiving IV abx for a UTI was observed with a peripheral IV in the left hand infusing medication, and the transparent dressing was unlabeled and undated. The resident’s record showed an order for ceftriaxone and a care plan for IV catheter monitoring, while facility policy required the dressing label to include the date, time, and initials. An RN and an LVN both confirmed the dressing should have been labeled and dated.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Care and IV Documentation Not Completed as Ordered
E
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

PICC care and IV documentation were not completed as ordered for a resident with a PICC placed for IV antibiotics. The admission assessment did not document key PICC details, and a clinic RN later observed a peeling dressing, an unclamped PICC, no legible dressing date, and no stat lock in use. The EMAR/ETAR did not show required connector or dressing changes on schedule, and no q12h maintenance flushes were documented after IV antibiotics stopped.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Line Not Monitored, Flushed, or Redressed
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with a PICC line and significant medical complexity, including bacteremia, sepsis, MS, and CHF, did not have the line properly monitored, flushed, capped, or redressed per facility policy and standards of care. The chart lacked PICC orders, care plan interventions, and documentation of site checks or dressing changes, and staff interviews confirmed uncertainty about the line’s care and documentation. When the resident arrived at the hospital, the PICC dressing was not intact, the hub was uncapped, and the line appeared to have shifted.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Change PICC Dressing as Ordered
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

Failure to change a resident’s PICC dressing as ordered. A resident with osteomyelitis had a PICC line with an order for the transparent dressing to be changed on admission and weekly, but the dressing was observed clean, dry, and intact and the resident stated it had not yet been changed. The TAR showed no documentation that the dressing was changed as ordered, and the DON confirmed the lack of documented evidence.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Pennsylvania

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Pennsylvania — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.