F0641 F641: Ensure each resident receives an accurate assessment.
D

Inaccurate MDS Coding for Diuretic Medication

Veranda Gardens Nursing & Rehabilitation CenterCincinnati, Ohio Survey Completed on 10-12-2024

Summary

The facility failed to ensure accurate coding of diuretic medication on the Minimum Data Set (MDS) assessments for a resident, which was identified during a review of medical records, facility documents, and staff interviews. The resident, who had a history of chronic obstructive pulmonary disease (COPD), heart failure, and hypertension, was receiving routine diuretic therapy as part of their care plan. Despite this, the MDS assessments for the resident did not reflect the administration of Lasix, a diuretic medication, during the specified seven-day look-back periods in June and September 2024. Interviews with the MDS Nurse and the Director of Nursing confirmed that the resident received diuretic medication during the relevant periods, and it should have been accurately coded on the MDS assessments. The MDS Nurse emphasized the importance of accurate coding due to the resident's medical conditions, which could be affected by the medication. Additionally, the facility lacked a policy on MDS accuracy, as revealed by a review of facility documents. The CMS Long-Term Care Facility Resident Assessment Instrument 3.0 User's Manual outlines the requirement to check if a diuretic medication was taken during the look-back period, which was not adhered to in this case.

Penalty

Inspection fine: $30,715
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0641 citations
Inaccurate MDS Assessments for Medication Use and Diagnoses
E
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A facility failed to ensure MDS assessments accurately reflected resident status for several residents. One resident’s admission MDS listed insulin injections even though she received liraglutide, while two other residents’ MDSs omitted antidepressant, opioid, and scheduled pain medication use despite active orders and MAR documentation. Another resident’s quarterly MDS failed to include respiratory failure as an active dx even though the record, orders, and resident interview confirmed the condition and oxygen use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate Resident Assessments
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate resident assessments were identified for multiple residents when MDS coding did not match the clinical record, observations, or staff statements. One resident was coded as having a restraint-related chair device despite no restraints being observed or ordered, another was coded as not receiving antibiotics despite MAR documentation of mupirocin use, and two other residents had missing or incorrect MDS entries for diagnoses, ROM status, and skin/wound conditions based on admission records, physician notes, wound care documentation, and staff interviews.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Weight Loss and Active Diagnoses
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate MDS coding affected two residents. One resident had significant weight loss documented in the EHR, but the quarterly MDS did not reflect the loss as required. Another resident with lung cancer and metastatic disease had an admission MDS that omitted active cancer diagnoses from section I. The MDS/LPN acknowledged the missing diagnosis, and the DON stated MDS assessments were expected to be coded accurately.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Assessments for Oxygen Use, Depression, and Range of Motion
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A facility failed to ensure MDS assessments accurately reflected resident status for multiple residents. One resident’s oxygen use was not captured in Section O despite PRN O2 orders and repeated oxygen saturation documentation, another resident’s MDS omitted oxygen use despite progress notes and an O2 order, a third resident’s MDS omitted depression despite a citalopram order, and a fourth resident’s MDS coded no ROM impairment even though PT identified quadriplegia with limitations in all extremities.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Weight Loss Coding
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A resident’s quarterly MDS incorrectly coded significant weight loss even though his documented weights did not show 5% loss in 1 month or 10% loss in 6 months. The MDS RN said she based the coding on weight fluctuations and medication changes rather than actual loss during the look-back period, and the resident’s care plan continued to reflect significant unplanned weight loss, poor intake, and anxiety.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Diabetes Medications
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate MDS coding was found for two residents whose diabetes meds were non-insulin injectables. One resident with ESRD and diabetes had Ozempic ordered, and another resident with CKD and diabetes had Mounjaro ordered, but both MDS assessments incorrectly coded insulin use and hypoglycemic drug class use. The MDS coordinator acknowledged the coding error but did not update the assessments after learning of the inaccuracy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Ohio

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Ohio — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙