F0908 F908: Keep all essential equipment working safely.
E

Dish Machine Maintenance Deficiency

Waterville Center For Health And RehabWaterville, Maine Survey Completed on 09-17-2024

Summary

The facility failed to maintain the kitchen's high-temperature dish machine in good repair and safe operating condition. During a kitchen tour, it was observed that the dish machine was operating at only 110 degrees Fahrenheit, below the required 150 degrees Fahrenheit for proper cleaning and sanitizing. The Kitchen Supervisor acknowledged the machine's issues, including inaccurate temperature readings and water leakage, which required the water to be turned off after each use to prevent flooding. Despite these problems, the dish machine continued to be used by the kitchen staff. Interviews with the Director of Facilities Operations and the Interim Food Service Director revealed that the dish machine had been serviced two weeks prior, but additional parts were needed for full repair. The Interim Food Service Director had instructed staff to wash dishes by hand in a three-bay pot sink, but was unaware that the dish machine was still in use. The Administrator confirmed the ongoing use of the malfunctioning dish machine and stated it would not be used until fixed. A subsequent work log indicated further issues with the machine, including a non-functioning booster and timer.

Penalty

Fine: $83,038
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0908 citations
Failure to Maintain Walk-In Freezer Condensation System
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

Staff failed to maintain essential kitchen equipment when the condensation pipe carrying condensate wastewater from the air condenser in the walk-in freezer was found leaking during a kitchen tour. The issue was confirmed in an interview with the kitchen manager and the corporate chef, who acknowledged the ongoing leak in the freezer’s condensation piping.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Ice Machine and Provide Ice for Residents
F
F0908 F908: Keep all essential equipment working safely.
Short Summary

The facility failed to maintain its ice machine in safe operating condition, resulting in no ice being available to residents for two days. Two cognitively intact residents, one with an indwelling catheter, neuromuscular bladder dysfunction, pressure ulcer, protein-calorie malnutrition, and paraplegia, and another with cerebral palsy, breast cancer, bipolar disorder, and a recent UTI, reported they had no ice and drank less because they preferred ice-cold fluids. CNAs, an LVN, dietary staff, and the Director of Maintenance confirmed the ice machine’s dispenser repeatedly came off track, that no ice was available on the units or in kitchen freezers, and that the usual process of stocking ice chests at the nurses’ station was not followed. The MDS coordinator, DON, administrator, and other department heads either were not notified in a timely manner or did not follow up after receiving notice, despite facility policy and manufacturer guidelines requiring proper maintenance and operation of the ice machine to assure a safe supply of ice.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Nonfunctional Phone System on Secured Behavioral Units
F
F0908 F908: Keep all essential equipment working safely.
Short Summary

The facility failed to maintain a functional phone system on its secured behavioral units. On the women’s secured behavioral unit, the nurse’s station phone was not working and a second unit phone was unplugged, leaving staff without a working line for incoming calls from families. On the men’s secured behavioral unit, the unit phone was also unplugged and not operational, and staff reported frequent problems with phones not working. The receptionist stated that after her work hours, calls are routed to nurse’s stations, but acknowledged there had been recent periods when phones were not working. The administrator did not view families’ inability to call in as a problem, noted that staff sometimes shared personal phone numbers with families, and confirmed there was no specific phone policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Kitchen Equipment Resulting in Improper Hot Food Temperatures
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

The facility failed to keep essential kitchen equipment in safe operating condition, leading to hot foods being served at improper temperatures. During lunch service, kitchen staff continued preparing trays after the last cart had left, and a test tray later showed ham, sweet potatoes, and collard greens all below appropriate hot-holding temperatures. A Certified Dietary Manager acknowledged the temperatures were not proper and reported that the plate warmer functioned correctly only briefly and that the pellet warmer, though initially reaching 135°F, cooled too quickly when taken out for use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Dishwasher in Working Order
F
F0908 F908: Keep all essential equipment working safely.
Short Summary

The facility did not maintain its dishwasher in working order over multiple extended periods, as documented in temperature logs and confirmed by staff interviews and surveyor observations. Due to recurring mechanical and chemical-dispensing problems, the dishwasher was frequently out of service, and technicians were repeatedly called for repairs. As a result, all meals were served in disposable Styrofoam containers with plastic utensils, and a resident reported difficulty cutting food and cutting through the container while eating. These conditions were inconsistent with the facility’s sanitization policy requiring equipment to be kept in good repair.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Lack of Documentation for HVAC Preventive Maintenance by Outside Contractor
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

Surveyors found that the facility did not maintain required documentation showing that an outside contractor was performing scheduled preventive maintenance on the HVAC system. The Maintenance Supervisor reported having no logs or reports of semi-annual HVAC service visits and acknowledged that such records should have been kept to monitor compliance and system function. The Administrator also confirmed that copies of HVAC maintenance records were not on file, despite facility policy assigning the maintenance director responsibility for maintaining maintenance schedules and related reports in the maintenance office.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer