F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
D

Failure to Monitor and Document Urinary Output

Villages At Historic Silvercrest TheNew Albany, Indiana Survey Completed on 07-22-2024

Summary

The facility failed to adequately monitor and document the urinary output of a resident who was experiencing bladder incontinence. The resident, who had a history of sepsis, urinary tract infection, acute kidney failure, overactive bladder, and dementia, was supposed to have their urinary output monitored following the removal of an indwelling Foley catheter. The care plan included interventions such as encouraging fluids, observing for signs of urinary tract infection, and assisting with toileting. However, documentation revealed significant gaps in monitoring, with the resident not urinating for extended periods, such as 15.5 hours and 22.5 hours, without appropriate follow-up or documentation. The resident's medical records showed inconsistencies in documenting urinary output, with instances where the resident did not urinate for long durations without any recorded intervention. For example, on one occasion, the resident did not urinate for 22.5 hours, and on another, for 9.5 hours. Despite these prolonged periods of no voiding, the records lacked documentation of any actions taken to address the issue. The resident was eventually admitted to the hospital with a diagnosis of sepsis, urinary tract infection, and urinary retention, indicating a failure in monitoring and responding to the resident's urinary needs. Interviews with facility staff revealed that there was a lack of consistent documentation practices and communication regarding the resident's urinary output. The LPN indicated that typically, the nurse practitioner would be notified if a resident hadn't urinated for 8 hours, but this was not consistently done. The DON acknowledged that CNAs did not always update the records at the end of their shifts, leading to incomplete documentation. Staff education records showed attempts to address these documentation issues, but the deficiency persisted, contributing to the resident's hospitalization.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0690 citations
Catheter Bag Left on Floor Beside Bed
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with an indwelling urinary catheter, ordered for urinary retention related to hydronephrosis, was observed in bed with the catheter collection bag lying flat on the floor beside the bed and containing urine. The resident said an aide had helped her back to bed after breakfast, and one aide confirmed she assisted the resident but forgot to hang the bag from the bed frame as she normally would. The DON and Administrator stated catheter bags were expected to be kept off the floor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Care and Securement Not Maintained
E
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Catheter care and securement were not maintained for three residents with indwelling catheters. One resident's drainage bag was found lying in bed with tubing under the leg and no strap in place, another resident's tubing was under the leg with no strap present, and a third resident received catheter care from a CNA who cleansed the catheter using a back-and-forth motion and reused the same wipe instead of cleaning away from the penis in one direction. The DON and other staff stated the bag should be below the bladder, the strap should secure the tubing, and catheter care should be performed using proper technique.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Drainage Bag Positioned Above Bladder Level
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a catheter for neurogenic bladder, impaired cognition, and total bowel/bladder incontinence had a catheter drainage bag repeatedly observed hooked on a wheelchair arm rest above bladder level. The tubing contained urine that had not drained down, the resident tried to move the tubing to drain it, and staff interviews confirmed the bag should have been positioned below the bladder; one RN also stated the resident was on antibiotics for a bladder infection.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Foley Bag Placed at Bladder Level During Incontinent Care
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Foley Bag Placed at Bladder Level During Care: A resident with an indwelling Foley catheter, severe cognitive impairment, and obstructive uropathy had his drainage bag emptied and then placed on the bed at bladder level during perineal care. Observation showed urine moving back toward the catheter insertion site while the resident was repositioned. Staff interviews confirmed the bag should remain below the bladder at all times, and the facility policy required the drainage bag to be positioned lower than the bladder to prevent backflow.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsecured Foley Catheter and Incomplete Incontinent Care
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a Foley catheter was observed with the tubing not secured to the leg during care, and staff acknowledged it should have been secured to prevent pulling and injury. In a separate observation, two CNAs provided incontinent care to another resident with bowel incontinence and an indwelling catheter but did not clean the inner thighs or right buttock area before applying a clean brief, despite the care plan and facility policy requiring thorough perineal cleansing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Bag and Tubing Left in Contact With Floor
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a catheter was observed with the catheter bag and tubing exposed outside the privacy bag and resting directly on the floor, and the resident moved the wheelchair over the bag. An RN later confirmed that catheter bag and tubing should not be in direct contact with the floor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Indiana

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Indiana — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙