F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
D

Failure to Ensure Staff Competency in Handling Specialized Equipment and Spinal Precautions

Accolade Healthcare Of PeoriaPeoria, Illinois Survey Completed on 05-08-2024

Summary

The facility failed to ensure staff were competent to care for a resident (R3) who required specialized equipment and spinal precautions following a lumbar fusion surgery and spinal stenosis. R3's hospital transfer papers and subsequent evaluations documented the need for a spine brace to be worn during transfers and ambulation, but not while in bed or a chair. Despite these instructions, R3 was observed multiple times in a wheelchair with the spine brace on, causing significant discomfort and pain. R3's care plan and physician's orders lacked documentation of spinal precautions and proper application of the spine brace, leading to improper handling and increased pain for R3. On one occasion, R3 was left in a wheelchair with the spine brace on, causing pain and discomfort. The call light was unreachable, and R3's roommate had to assist in calling for help. When staff finally arrived, they improperly used a mechanical lift without removing the spine brace, further exacerbating R3's pain. Additionally, a Certified Nurse Aide admitted to putting the brace on incorrectly. R3 was left in bed with the call light out of reach and reported severe pain and indigestion. The dressing covering R3's back incision was found to be improperly applied, and staff used incorrect techniques that involved twisting motions, contrary to the prescribed spinal precautions. Interviews with staff and R3's healthcare power of attorney revealed that staff were not adequately educated on the use of the spine brace and spinal precautions. The physical therapist confirmed that staff should have been using the log roll technique and removing the spine brace during transfers. The facility's policy on transfers required proper training for staff on the use of mechanical lifts, which was not adhered to in R3's case. The lack of staff education and adherence to prescribed precautions led to significant pain and improper care for R3.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0726 citations in Ohio
Insufficient Qualified Nursing and Respiratory Staff for Ventilator-Dependent Residents
D
F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
Short Summary

The facility failed to ensure adequate RN or RT coverage for two ventilator-dependent residents whose care plans and orders required frequent ventilator checks, trach care, suctioning, HME and circuit changes, and close monitoring of respiratory status. On at least one night shift, only LPNs were on duty with no RN or RT present, despite these residents’ dependence on mechanical ventilation and tracheostomies. The DON acknowledged there was no RN or RT on that shift, believed prior daytime RN presence met requirements, allowed LPNs to perform ventilator care without certification or documented competency, and was unsure whether such care was within LPN scope of practice. Cited literature from the National Library of Medicine noted that mechanical ventilators are complex, require specific training, and are best managed by RTs, with improper management linked to poor outcomes.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Ensure Competent IV Therapy Administration by Agency LPN
D
F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
Short Summary

A resident with a PICC line for IV cefepime therapy and multiple comorbidities received IV medication from an LPN who attached IV tubing directly to the open end of the PICC line without a needleless connector, after cleaning only the open hub. The LPN stated that PICC lines do not have valves, despite reporting prior IV therapy training. Facility leadership and HR reported they did not maintain competency or training records for agency staff, and one agency only verified licensure while another provided a self-assessment showing the LPN rated IV skills as limited and requiring supervision, even though the facility’s contract assigned responsibility for orientation, education, and competency of agency staff to the facility.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Uncertified Staff Member Allowed to Perform CNA Duties
F
F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
Short Summary

A staff member was hired and worked in the capacity of a CNA for an extended period without ever obtaining CNA certification or being listed on the Nurse Aide Registry. HR records and interviews showed that the individual completed two Nurse Aide Training classes and repeatedly failed the written competency test, yet was still permitted to perform CNA duties and provide direct care to residents. The personnel file contained only training completion certificates and no verification of an active CNA certification or registry check, affecting care provided to all residents in the facility.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Train Staff on Mechanical Lift Use and Adherence to Transfer Protocols
E
F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
Short Summary

A CNA transferred a resident with cognitive and physical impairments using a mechanical lift without a second staff member present and without having received proper training on the equipment, in violation of facility policy requiring two trained staff for such transfers.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide Qualified Staff for IV Medication Administration via PICC Line
D
F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
Short Summary

A resident with complex medical needs did not receive prescribed IV vancomycin through a PICC line because no RN was available to administer the medication. The medication was delivered, but scheduled doses were missed due to the absence of qualified staff, despite facility policy requiring timely administration of medications.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unqualified LPNs Removed Midline IV Catheters
D
F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
Short Summary

Two residents with midline IV catheters for UTI treatment had their catheters removed by an LPN who lacked documented training and was not qualified under state regulations or facility policy to perform this procedure. Staff interviews and record reviews confirmed that the LPN did not have the required competencies, and there was confusion among staff about the scope of LPN practice regarding midline IV removal.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

65.1% of Ohio facilities received at least one citation during their inspection in the last 12 months.Will yours be survey-ready?

Surveyors issued 55 serious citations across Ohio in the last 12 months. See exactly what they're citing.

Get ready for your next survey

See what surveyors are citing in Ohio and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release May 27, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙