Above average — CMS composite of the measures below.
The next survey window likely opens around May 2027
Estimate from public CMS data, current as of July 2026. Survey timing is at the state agency's discretion.
Citation history
Health deficiencies cited at Lila Doyle Post Acute during CMS and state inspections, most recent first.
A resident with severe dementia and high fall risk was taken outside by an LPN, left without direct staff supervision, and positioned near an unsecured gate with wheelchair brakes unlocked. While the receptionist was occupied with other duties, the resident rolled down a sloped walkway, fell from the wheelchair, and sustained a left femoral neck fracture and skin tears. In separate incidents, two other severely cognitively impaired, high fall-risk residents who were care planned and ordered for chair sensor alarms were found with their alarms switched off: one resident stood and fell in a common area, lost consciousness, and was later diagnosed with a nondisplaced pelvic fracture, and another was observed seated in a scoot chair with the alarm box in the off position, leaving the intervention ineffective.
Failure to Provide Adequate Supervision and Maintain Fall-Prevention Measures
Penalty
Summary
The deficiency involves the facility’s failure to keep the environment free of accident hazards and to provide adequate supervision and fall-prevention interventions for multiple residents at high risk for accidents. One resident with vascular dementia, severe cognitive impairment (BIMS score 0), gait and balance problems, muscle weakness, vision/hearing impairment, and benign essential tremors was care planned and assessed as high risk for falls. On the day of the incident, this resident was taken from the second floor to an outdoor area by an LPN who was not the assigned nurse, along with two cognitively intact residents who had requested to go outside. The LPN left all three residents outside and returned to the unit without confirming supervision arrangements with the assigned nurse and without locking the cognitively impaired resident’s wheelchair brakes. The gate that helped secure the patio area was not latched, and the facility did not routinely use the padlock on the gate except during high windstorms. While the residents were outside, the receptionist was at the front desk answering phones and assisting visitors and did not continuously monitor the residents. After approximately 15–20 minutes, one of the other residents stood up from their wheelchair and began yelling for help after observing the cognitively impaired resident roll down a sloped walkway toward a gazebo. Staff responding to the receptionist’s call for help found the resident lying on their left side on the sidewalk with the wheelchair flipped on top of them, approximately 30–55 feet from the front door. The resident was screaming in pain, had skin tears on the left arm and finger, an externally rotated left leg, and complained of pain in the buttocks and left hip. Emergency medical services transported the resident to the hospital, where imaging showed an impacted left femoral neck fracture. Interviews with the DON, nurse practitioners, and the resident’s responsible party confirmed that this resident was not appropriate to be outside without direct staff supervision and that the facility had no policy defining which residents could go outdoors alone or criteria for levels of supervision. The facility also failed to implement and maintain fall-prevention interventions for two additional residents with severe cognitive impairment and high fall risk. One resident with aphasia, dementia, muscle weakness, gait abnormalities, unsteadiness, and a history of frequent falls was care planned for a wheelchair sensor alarm per family request, and the fall risk evaluation identified the resident as high risk. During supper, this resident was found on the floor in the common area, unconscious, after staff heard a loud bang and a verbal cue telling the resident to sit down. The resident had hit their head, lost consciousness, developed a large bruise on the left forehead, and later complained of left hip pain; hospital records documented a nondisplaced pubic body fracture. Post-fall checks by CNAs and the RN revealed the resident’s chair alarm box was in the off position and had not been turned back on after toileting. Another resident with Parkinson’s disease, dementia, lack of coordination, muscle weakness, unsteadiness, and gait abnormalities had severe cognitive impairment (BIMS score 2) and was care planned and ordered to have sensor pads in bed and wheelchair every shift for safety. The MDS documented daily use of a chair alarm. During surveyor observation, this resident was seated in a scoot chair in a common area with a sensor chair pad in place, but the alarm box switch was in the off position, rendering the alarm ineffective. The assigned LPN and the DON confirmed that the alarm in the off position would not alert staff when the resident shifted weight or attempted to get up, and that staff were expected to follow all care-planned interventions. These findings show that for three high-risk residents, the facility did not ensure appropriate supervision, secure environmental controls, or consistent use of ordered fall-prevention devices, resulting in accidents and injuries for two of the residents.
What surveyors are citing around you — mapped
All 10 risk areas, ranked with evidence
Repeat citations, what's rising near you, and quality measures — ranked so department heads know exactly where to look first.
Illustrative
What surveyors actually found near you
We read the 35 citations issued within 25 miles in the last 12 months — and tell you exactly what happened, in plain English, matched to your record.
Resident with a documented fall history left unattended on the patio; found on the ground with a hip fracture.
Walk-in cooler logs missing for 12 days; expired supplements in the medication room fridge.
Illustrative
A prioritized, do-first checklist
Every risk area becomes concrete audit steps drawn from real citations at facilities like yours — run them this week, before your window opens.
Illustrative
Risk indicators are statistical estimates from public CMS data — not predictions, findings, or compliance advice.
Nursing homes near Seneca
How nearby facilities compare on the same public inspection record.
| Facility | Distance | Overall rating | Citations, 12 mo | Serious (J–L) |
|---|---|---|---|---|
| Seneca Health & Rehabilitation Center | 3 mi | ★★★★★ | 4 | 0 |
| Pruitthealth - Pickens | 12.8 mi | ★★★★★ | 4 | 0 |
| Manna Post Acute | 21 mi | ★★★★★ | 6 | 0 |
| Pruitthealth - Toccoa | 21.4 mi | ★★★★★ | 5 | 0 |
| Linley Park Post Acute | 21.8 mi | ★★★★★ | 8 | 0 |
Every risk area ranked, a do-first checklist, and your local survey patterns
Built specifically for Lila Doyle Post Acute.
100% money-back within 48 hours.
Trusted data, never guesswork. Every citation, penalty, rating and Plan of Correction on this page is sourced from public CMS records (latest release July 2026) and official state health department websites.