Catheter Care and UTI Prevention Deficiencies
Summary
The facility failed to ensure appropriate care for residents with indwelling urinary catheters and failed to provide care to prevent urinary tract infections for two residents reviewed for incontinent care. One resident had a history of urinary tract infections, a neurogenic bladder, and an indwelling catheter, and was dependent on staff for toileting and other ADLs. Her care plan directed staff to provide incontinent care at least every two hours and as needed and to monitor for signs and symptoms of UTI. During observation, her catheter bag was found more than half full, with urine reaching the 1800 mL line on a 2000 mL bag, and it had not been emptied as needed. The same resident had prior lab results showing E. coli and cloudy urine, and her record showed multiple antibiotic treatments for UTI and an active order for methenamine hippurate for prophylactic treatment related to flaccid neuropathic bladder. The resident’s representative stated the catheter bag was occasionally full and that staff were called to empty it. A CNA stated the bag should have been emptied before it reached 1800 mL because urine could travel back up the tube and cause infection, and that a full bag could also cause pulling on the tube due to gravity. The DON stated the bag should have been emptied when urine reached 200 mL to avoid backflow, and that staff should have been checking the bag every two hours and as needed and before shift change. For another resident with parkinsonism, neuromuscular dysfunction of the bladder, intact cognition, and dependence on staff for ADL care, the facility failed to provide catheter care in accordance with the resident’s needs and the facility policy. During observed foley and incontinent care, a CNA placed the catheter bag on the bed for about ten minutes, did not hold the catheter tubing while cleaning the peri area, and the stabilization device was attached but the tubing was not secured in the loop. The CNA stated the bag should not have been placed on the bed because urine could flow back into the bladder and cause infection, and that the tubing should have been held to prevent pulling and pain. The WCN and DON both stated the bag should have remained below the bladder, the tubing should have been held during care, and the stabilization device was not functioning properly because it did not keep the tubing secured.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.