F0759 F759: Ensure medication error rates are not 5 percent or greater.
D

Medication Error Rate Exceeded Due to Crushed Potassium Chloride ER

Avir At HoustonHouston, Texas Survey Completed on 07-10-2026

Summary

The facility failed to ensure that the medication error rate remained below 5 percent. Surveyors identified 2 medication errors out of 26 opportunities, resulting in a 7% error rate, involving two residents and one medication aide. The errors involved Potassium Chloride ER being administered in a manner that did not follow the physician’s order and pharmacy instructions. Resident #1 was admitted with diagnoses including hypertension, low potassium, Alzheimer’s disease with early onset, anorexia, a history of transient ischemic attack, cerebral infarction, and a personal history of breast cancer. Her MDS reflected severe cognitive impairment with a BIMS score of 4, extensive assistance needed with ADLs, and limited assistance with eating. Her care plan and physician’s order directed Potassium Chloride ER 20 mEq, 1 tablet by mouth daily. During observation, MA B removed the tablet from the blister pack, then crushed it with other medications and mixed it in yogurt before giving it to the resident, despite the blister pack stating to swallow whole and not chew or crush. Resident #2 was admitted with diagnoses including fatigue, gangrene, aphasia, chest pain, shortness of breath, low potassium, and hypertension. Her MDS indicated severe cognitive impairment, extensive assistance with ADLs, and limited assistance with eating. Her physician’s order directed Potassium Chloride ER 10 mEq by mouth daily. During observation, MA B again removed the tablet from the blister pack, crushed it with other medications, and mixed it in yogurt. When the surveyor intervened, MA B checked the blister pack, saw the instruction to swallow whole and not chew or crush, and still administered the potassium by mouth. MA B later stated she had not checked the blister pack and acknowledged that crushing the potassium would not work as it should in the blood.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations
Medication Error Rate Exceeded Threshold During Eye, Ear, and Nebulizer Administration
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

An LPN contributed to a medication error rate of 10.71% after 3 errors were found in 28 observed medication opportunities. The LPN administered eye drops and ear drops to one resident without preventing the resident from wiping the medication away, and left another resident unsupervised during a nebulizer treatment without monitoring the response or cleaning the equipment afterward. Record review showed the resident receiving the nebulizer had no documentation supporting self-administration, and the facility's procedures required assessment and direct administration for these treatments.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Exceeded Allowed Rate
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication administration errors exceeded the allowed rate, with surveyors identifying multiple dose discrepancies and an enteral medication error during observed med passes. An MA gave a resident the wrong ferrous sulfate dose, another MA gave a resident several medications at incorrect strengths, and an LVN used another resident’s MiraLAX and did not complete the ordered G-tube water flushes before administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication error rate exceeded the allowed threshold
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication error rate exceeded the allowed threshold. Surveyors calculated a 6.25% error rate based on 32 medication opportunities with 2 errors. In one case, an LPN gave a resident the wrong magnesium/calcium tablet strength compared with the active order for hypomagnesemia. In another, an LPN administered vitamin D3 400 units even though the resident’s order called for cholecalciferol 4000 units for vitamin D deficiency, and staff noted the pharmacy label still showed 400 units.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Threshold; Insulin Pen Not Primed and Inhaler Rinse Not Completed
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

The facility’s medication error rate was 6.9%, with 2 errors found in 4 observed med passes. One nurse gave an insulin dose without priming the pen first, and another did not ensure a resident rinsed and spit after using a steroid-containing inhaler. The residents involved had DM and COPD, respectively, and both were moderately cognitively impaired.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Standard During G-Tube Medication Administration
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication Error Rate Exceeded Standard During G-Tube Medication Administration. Surveyors found a 27.59% medication error rate during observation of medication administration. An LPN crushed multiple meds together, mixed them with water, and administered them through a resident’s g-tube without giving each medication separately. The resident had encephalopathy, dysphagia, malnutrition, severe cognitive impairment, and required tube feeding for nutrition. The resident’s orders did not include permission to combine the tablets, and the DON and ADON stated meds for tube administration should not be cocktailed.

Inspection fine: $19,635
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Exceeded Allowed Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication administration errors exceeded the allowed rate when seven errors were found in 31 opportunities. A nurse gave several scheduled meds to one resident more than 2 hours late, and another nurse crushed and gave three meds together through a G-tube to another resident instead of administering each med separately with flushes between doses, contrary to the DON’s expectations, the consultant pharmacist’s guidance, and facility policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Texas

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Texas — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.