Respiratory Equipment and Suctioning Not Maintained as Ordered
Summary
Respiratory care was not provided as ordered for multiple residents receiving tracheostomy and ventilator-related services. Resident 1 was admitted with hypoxia, chronic respiratory failure, and ventilator dependence, and the MDS indicated the resident received tracheostomy care and was on an invasive mechanical ventilator. On observation, the resident’s t-piece had dry blood and mucus buildup, and this was seen again later the same day. The DON stated the dry blood and mucus could obstruct airflow or become dislodged and block the airway. RT 1 stated the t-piece should be changed twice weekly and as needed, including when blood or mucus is built up, and the facility policy required the suction catheter to be changed twice weekly and as needed to decrease infection risk. Resident 3 was admitted with respiratory failure and ventilatory support via tracheostomy. The MDS indicated the resident was comatose, in a persistent vegetative state/no discernible consciousness, and dependent for multiple activities of daily living, with tracheostomy care and invasive mechanical ventilation. The physician ordered ongoing aerosol at 35% FIO2 with a cool aerosol t-piece and to keep SPO2 greater than 92%. During observation, the resident’s t-piece was not connected to the cool aerosol. The DON stated the t-piece should always be connected to the cool aerosol because the resident could go into respiratory distress if it was not connected, and stated staff were not following the MD order when the t-piece was not connected to the cool aerosol or oxygen. Resident 8 was admitted with acute and chronic respiratory failure with hypoxia, gastrostomy, and tracheostomy status. The MDS indicated the resident was comatose and in a persistent vegetative state/no discernible consciousness, and the care plan identified a potential for infection related to the tracheostomy tube with interventions for tracheostomy care every shift and suction every 2 hours and as needed. The monthly orders also directed tracheal suction every 2 hours and as needed. During observation, mucus was noted in the inner t-piece and was overflowing out of the t-piece down the resident’s body and onto a towel and the call light. The MDS nurse stated the t-piece needed to be changed and the mucus needed to be suctioned, and the DON stated the resident needed suctioning every 2 hours and as needed because of excessive mucus. Resident 14 was admitted with acute and chronic respiratory failure, tracheostomy status, and gastrostomy status. The MDS indicated the resident’s cognitive skills for daily decision making were intact, and the care plan identified a potential for infection related to the tracheostomy tube with tracheostomy care every shift and suction every 2 hours and as needed. During observation, the Yankauer was left uncovered attached to the suction tube and another used Yankauer with dried mucus was left on the resident’s bed. RN 1 stated the Yankauers were dirty, the attached Yankauer was supposed to be kept in a bag, and the used Yankauer should have been discarded rather than left on the bed. The DON stated the Yankauer should be placed in a bag to avoid cross contamination and the detached used Yankauer should be disposed of rather than left on the bed.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.