F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
E

Respiratory Equipment and Suctioning Not Maintained as Ordered

Alhambra Hospital Med Ctr Dp/snfAlhambra, California Survey Completed on 07-17-2026

Summary

Respiratory care was not provided as ordered for multiple residents receiving tracheostomy and ventilator-related services. Resident 1 was admitted with hypoxia, chronic respiratory failure, and ventilator dependence, and the MDS indicated the resident received tracheostomy care and was on an invasive mechanical ventilator. On observation, the resident’s t-piece had dry blood and mucus buildup, and this was seen again later the same day. The DON stated the dry blood and mucus could obstruct airflow or become dislodged and block the airway. RT 1 stated the t-piece should be changed twice weekly and as needed, including when blood or mucus is built up, and the facility policy required the suction catheter to be changed twice weekly and as needed to decrease infection risk. Resident 3 was admitted with respiratory failure and ventilatory support via tracheostomy. The MDS indicated the resident was comatose, in a persistent vegetative state/no discernible consciousness, and dependent for multiple activities of daily living, with tracheostomy care and invasive mechanical ventilation. The physician ordered ongoing aerosol at 35% FIO2 with a cool aerosol t-piece and to keep SPO2 greater than 92%. During observation, the resident’s t-piece was not connected to the cool aerosol. The DON stated the t-piece should always be connected to the cool aerosol because the resident could go into respiratory distress if it was not connected, and stated staff were not following the MD order when the t-piece was not connected to the cool aerosol or oxygen. Resident 8 was admitted with acute and chronic respiratory failure with hypoxia, gastrostomy, and tracheostomy status. The MDS indicated the resident was comatose and in a persistent vegetative state/no discernible consciousness, and the care plan identified a potential for infection related to the tracheostomy tube with interventions for tracheostomy care every shift and suction every 2 hours and as needed. The monthly orders also directed tracheal suction every 2 hours and as needed. During observation, mucus was noted in the inner t-piece and was overflowing out of the t-piece down the resident’s body and onto a towel and the call light. The MDS nurse stated the t-piece needed to be changed and the mucus needed to be suctioned, and the DON stated the resident needed suctioning every 2 hours and as needed because of excessive mucus. Resident 14 was admitted with acute and chronic respiratory failure, tracheostomy status, and gastrostomy status. The MDS indicated the resident’s cognitive skills for daily decision making were intact, and the care plan identified a potential for infection related to the tracheostomy tube with tracheostomy care every shift and suction every 2 hours and as needed. During observation, the Yankauer was left uncovered attached to the suction tube and another used Yankauer with dried mucus was left on the resident’s bed. RN 1 stated the Yankauers were dirty, the attached Yankauer was supposed to be kept in a bag, and the used Yankauer should have been discarded rather than left on the bed. The DON stated the Yankauer should be placed in a bag to avoid cross contamination and the detached used Yankauer should be disposed of rather than left on the bed.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0695 citations
Oxygen equipment not maintained per order
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

A resident who required oxygen therapy for SOB had an oxygen bubbler that was overdue for replacement, despite a TAR directing weekly changes of oxygen supplies including the bubbler and tubing. Staff confirmed the bubbler should have been changed weekly, and the DON and staff educator stated nurses were expected to follow the provider order as written and that all disposable oxygen pieces were to be changed weekly.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Bi-pap Therapy Not Ordered or Verified at Admission
E
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

A resident with COPD, acute respiratory failure with hypercapnia, and oxygen dependence was admitted with prior records showing nightly Bi-pap use and specific settings, but the facility did not have a Bi-pap order or settings in the chart and the baseline care plan did not address oxygen or Bi-pap. The resident reported he went without Bi-pap for three nights because a connector piece was missing, while the hospice RN, admitting LPN, ADON, and DON each stated they were unaware of the machine or did not verify the equipment and orders at admission.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Respiratory Care and Tracheostomy Care Not Provided as Ordered
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

Respiratory care was not provided as ordered for one resident receiving O2, as the NC tubing was not dated. Tracheostomy care was also not provided as ordered for another resident: heavy thick mucus was visible under the trach, the ATM mask was soiled with mucus, the ATM and nebulizer tubing were not dated or stored in a bag, and the suction catheter tubing end was not stored in a bag. An RN confirmed the findings.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Change Oxygen Equipment per Physician Orders
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

The facility failed to follow physician orders for oxygen equipment for two residents with COPD-related diagnoses. Observations showed each resident’s O2 tubing and water bottle remained dated and unchanged beyond the ordered weekly schedule, and the DON confirmed the equipment should have been changed per the orders.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Ordered Continuous Oxygen
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

Failure to maintain ordered continuous O2: A resident with stroke and COPD was observed without his NC while a CNA waited for a portable O2 unit to be filled. The CNA then applied the NC but did not turn on the liquid portable O2, and later wheeled the resident to the nurse’s station to have the nurse set the unit to the ordered liter flow. The resident’s physician had ordered continuous O2 2L to 4L NC.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Storage of CPAP Mask and Oxygen Tubing
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

Improper Storage of CPAP Mask and Oxygen Tubing: A resident with COPD, DM, dialysis dependence, and continuous O2 orders had his CPAP/NIV mask observed lying on the bedside table and his O2 tubing wrapped under the concentrator handle instead of being stored in a sanitary container or bag. Staff interviews confirmed the equipment should be stored in a bag when not in use, but it was not being kept that way during observation.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.