Failure to Administer Ordered Enteral Nutrition and Water Flushes
Summary
The facility failed to ensure enteral nutrition and free water flushes were administered as ordered for two residents with gastrostomy tubes. One resident was admitted with diagnoses including DM, quadriplegia, dysphagia, sepsis, and a G-tube, and was dependent for daily living and personal hygiene. The resident had significant weight loss, and the RD recommended a revised tube feeding regimen after the resident returned from the hospital. The record review and observations showed the feeding pump was set at 50 ml/hr instead of the ordered 55 ml/hr, and nursing staff acknowledged the pump’s cumulative volume was not routinely reset, so they could not determine how much formula had actually been delivered. The same resident’s free water flush order was documented as completed, but the LVN stated he did not know what FWF meant and admitted he was checking the MAR box without understanding the order. The second resident was admitted with anoxic brain damage, a G-tube, and persistent vegetative state, and was dependent for all ADLs and personal hygiene. During observation, the resident’s tube feeding was running at the ordered rate, but the feeding bottle still had a large remaining volume and the pump’s cumulative volume had not been cleared. Nursing staff stated the facility practice was to stop tube feedings at 8:00 a.m. and to infuse for 20 hours with a 4-hour rest period, even though the physician order was to continue until the total ordered amount was completed. When the G-tube was found clogged, the RN attempted to flush it multiple times without success and could not complete the ordered feeding and water flushes. The RN and DON acknowledged that because the cumulative volume was not reset, staff could not verify whether the ordered amount of enteral nutrition had been received. The DON stated staff relied on MAR documentation and that if staff did not follow the physician’s orders, the MAR would not accurately reflect what was administered. The DON also acknowledged staff were not routinely clearing the cumulative volume on the feeding pump and that documenting administration without understanding the order would constitute false documentation. The RD stated nursing staff were responsible for implementing the nutrition recommendations and accurately documenting administration, and after being informed of the pump settings and unclogged feeding issues, stated it was reasonable to conclude the residents did not receive the ordered enteral nutrition and hydration. The facility’s policies required enteral nutrition to be provided as ordered, complete orders to include flushing instructions, and medications to be administered in accordance with the orders.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.