Improper Mattress Settings and Unsafe Wound Care
Summary
The facility failed to ensure that specialty low air loss mattresses were accurately set and monitored according to resident weight for three residents. One resident with dysphagia, peripheral vascular disease, and depression was observed in bed with a specialty mattress pump set to 250 lbs, while the resident’s last known weight was 187 lbs. The resident’s record did not include a physician order for the specialty mattress, and the treatment record did not show documentation that the mattress was being monitored for function and proper placement. A second resident with hemiplegia and hemiparesis following cerebral infarction was observed with a specialty mattress pump set to 250 lbs, although the resident’s weight was documented as 152 lbs. The resident’s record also did not include a physician order for the specialty mattress, and the treatment record did not include documentation that the mattress was being monitored for function and proper placement. The DON confirmed that specialty mattresses should be set to the resident’s current body weight and that the mattress had been ordered to help prevent skin breakdown. A third resident with Alzheimer’s disease and diabetes mellitus was observed with a specialty mattress pump set to 450 lbs, while the resident’s weight was documented as 133 to 135 lbs. The resident had a stage 2 pressure ulcer and pressure ulcers on both buttocks, and the care plan included a pressure-relieving mattress. The current order summary included a low-air-loss mattress with a check function every shift, but the RN confirmed the pump was set at 450 lbs and acknowledged signing the TAR indicating the mattress had been checked even though it had not been properly monitored. The facility also failed to provide necessary treatment and services for the resident with the pressure ulcer in a manner consistent with professional standards of practice. During observation of wound care, the RN cleansed the wound from the peri-wound to the inner wound bed, then repeated the same technique, and used the same applicator to apply zinc oxide barrier cream to both the peri-wound and the wound bed. The CNA repositioned the resident without donning a gown despite the resident being under Enhanced Barrier Precautions for a wound. The RN also did not remove trash from the room or disinfect the overbed table after the treatment was completed. The DON confirmed that signage should have been posted, the CNA should have worn a gown, the wound should have been cleansed and treated from the wound bed to the peri-wound, and the table should have been disinfected after the treatment.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.