Failure to Administer Oxygen According to Physician Orders
Summary
The facility failed to provide appropriate oxygen therapy for two residents by not administering oxygen according to physician orders. One resident had diagnoses including Parkinson’s disease with dyskinesia, COPD, hemiplegia affecting the left side, and depression, along with a history of aspiration pneumonia, dysphagia, and acute hypoxic respiratory failure. During observation, the resident was found in bed wearing a nasal cannula with oxygen running at 5 LPM, and when the surveyor entered the room the resident stated, “I cannot breathe.” The charge nurse later confirmed the resident was on 5 LPM, obtained a pulse oximeter reading of 93% to 94%, and attempted to feed the resident, who stated, “It is hard to swallow.” Record review for this resident showed a physician order for oxygen at 2 L if SpO2 was below 90% or if shortness of breath occurred every 8 hours as needed, with head of bed elevated. The care plan addressed COPD and ineffective gas exchange and included oxygen therapy at 2 L as needed for shortness of breath, but there were no care plans related to the resident being on 5 L oxygen or to the behavior described by staff. The MAR showed the PRN oxygen order for 2 L was left blank on the dates reviewed while oxygen was observed running at 5 L via nasal cannula. The regional clinical supervisor stated the charge nurse was suspended pending investigation related to failure to follow procedures after being notified of the resident’s breathing difficulty, and the source of the 5 L oxygen not matching the physician order was unknown. A second resident was observed in a wheelchair with a portable oxygen concentrator, and the surveyor found the needle in the red area indicating the tank was empty. Facility staff also acknowledged the tank was empty. The resident was alert and oriented, and the assigned LPN stated she had just changed the oxygen tank and that the resident would tell staff if it needed to be changed. The LPN said the facility checked oxygen every morning but could not explain why the tank was empty. The resident’s record showed diagnoses including COPD, CHF, hypertension, and peripheral vascular disease, a BIMS score of 15 out of 15, and a physician order for oxygen at 3 L/min via nasal cannula every shift. The care plan noted the resident had behavior problems and was non-compliant with oxygen use, with an intervention to ensure portable oxygen was functioning and accessible at all times.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.