F0759 F759: Ensure medication error rates are not 5 percent or greater.
D

Medication Administration Errors Exceeded Allowed Rate

Troy Hills CenterParsippany, New Jersey Survey Completed on 04-09-2026

Summary

The facility failed to ensure that medications were administered without an error rate of 5% or greater during a observed medication pass. Surveyors observed 3 nurses administering medications to 4 residents, with 28 opportunities for error and 3 observed errors, resulting in a medication administration error rate of 10.7%. The deficient practice was identified for 3 of 4 residents and involved 2 of the 3 nurses observed. For one resident, an active order was for vitamin D3 oral tablet 50 mcg, 1 tablet by mouth daily, but the LPN could not find the ordered strength in the med cart and administered two 25 mcg tablets instead. The LPN stated the medication should be a stock med and that the order would have to be changed. For another resident, an active order for Tecfidera 240 mg delayed-release capsule, with directions not to crush medication, was observed being opened and sprinkled over applesauce before administration. Manufacturer prescribing information reviewed by the surveyor stated the capsule should be swallowed whole and intact and should not be crushed, chewed, or sprinkled on food. For a third resident, an active order for Voltaren gel 1% to both knees twice daily was observed being prepared by squeezing an undetermined amount into a plastic dosage cup. The resident stated they did not want the Voltaren, and the LPN did not administer it and disposed of it. During interview, the DON stated staff should follow physician orders as written, that Voltaren gel could not be accurately measured in a plastic dose cup, and that staff should read and understand medication labels and cautions. The facility policy reviewed stated long-acting or enteric-coated dosage forms should generally not be crushed and medications are to be administered in accordance with written physician orders.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations
Medication Error Rate Exceeded Threshold During Eye, Ear, and Nebulizer Administration
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

An LPN contributed to a medication error rate of 10.71% after 3 errors were found in 28 observed medication opportunities. The LPN administered eye drops and ear drops to one resident without preventing the resident from wiping the medication away, and left another resident unsupervised during a nebulizer treatment without monitoring the response or cleaning the equipment afterward. Record review showed the resident receiving the nebulizer had no documentation supporting self-administration, and the facility's procedures required assessment and direct administration for these treatments.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Exceeded Allowed Rate
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication administration errors exceeded the allowed rate, with surveyors identifying multiple dose discrepancies and an enteral medication error during observed med passes. An MA gave a resident the wrong ferrous sulfate dose, another MA gave a resident several medications at incorrect strengths, and an LVN used another resident’s MiraLAX and did not complete the ordered G-tube water flushes before administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication error rate exceeded the allowed threshold
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication error rate exceeded the allowed threshold. Surveyors calculated a 6.25% error rate based on 32 medication opportunities with 2 errors. In one case, an LPN gave a resident the wrong magnesium/calcium tablet strength compared with the active order for hypomagnesemia. In another, an LPN administered vitamin D3 400 units even though the resident’s order called for cholecalciferol 4000 units for vitamin D deficiency, and staff noted the pharmacy label still showed 400 units.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Threshold; Insulin Pen Not Primed and Inhaler Rinse Not Completed
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

The facility’s medication error rate was 6.9%, with 2 errors found in 4 observed med passes. One nurse gave an insulin dose without priming the pen first, and another did not ensure a resident rinsed and spit after using a steroid-containing inhaler. The residents involved had DM and COPD, respectively, and both were moderately cognitively impaired.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Standard During G-Tube Medication Administration
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication Error Rate Exceeded Standard During G-Tube Medication Administration. Surveyors found a 27.59% medication error rate during observation of medication administration. An LPN crushed multiple meds together, mixed them with water, and administered them through a resident’s g-tube without giving each medication separately. The resident had encephalopathy, dysphagia, malnutrition, severe cognitive impairment, and required tube feeding for nutrition. The resident’s orders did not include permission to combine the tablets, and the DON and ADON stated meds for tube administration should not be cocktailed.

Inspection fine: $19,635
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Exceeded Allowed Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication administration errors exceeded the allowed rate when seven errors were found in 31 opportunities. A nurse gave several scheduled meds to one resident more than 2 hours late, and another nurse crushed and gave three meds together through a G-tube to another resident instead of administering each med separately with flushes between doses, contrary to the DON’s expectations, the consultant pharmacist’s guidance, and facility policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across New Jersey

Get a heads-up on the newest immediate-jeopardy (J–L) citations in New Jersey — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report