Tube Feeding Care and Documentation Deficiencies
Summary
The facility failed to follow professional standards of practice and physician orders for residents receiving enteral feedings, resulting in deficient care for three residents with feeding tubes. The report identified problems with tube feeding administration, documentation, and equipment handling for residents who had diagnoses including dysphagia, failure to thrive, stroke, diabetes, and dependence on enteral nutrition. The facility’s own tube feeding policy required feedings to be given per physician order, with tubing and piston syringes changed on specified schedules. For one resident, the surveyor observed a Glucerna 1.5 tube feeding bottle dated two days earlier while the pump was off, then later observed a new bottle running at 50 mL/hr. The resident’s record showed an order for continuous Glucerna 1.5 at 50 mL/hr via G-tube, along with orders to document oral intake on tray tickets. The medication administration audit showed the tube feed was signed as hung on consecutive evenings, but staff interviews revealed confusion about when the feed was started and how the volume was being tracked. The DON stated that when the 1,000 mL bottle emptied, staff should hang a new bottle to run the remaining 200 mL and document it when hung. For another resident, the record showed an order to check gastric residual before continuous feeding and to hold and notify the physician if residuals exceeded specified amounts. However, the eMAR had been set up with a field for temperature instead of residual, and nurses documented temperatures and completion checks rather than residual amounts for multiple days. An LPN acknowledged she had documented temperatures instead of residuals and stated she should have read the order correctly. The UM and DON both confirmed the documentation was wrong and that the nurses should have notified the physician and had the order corrected. For the third resident, the surveyor observed a heavily soiled feeding pump area, bedside table, air mattress pump, and floor with a tan substance, along with a piston syringe labeled with the resident’s room and bed number and dated two days earlier. The resident stated medications were crushed and given through the feeding tube and that staff used the syringe for medications and hydration. The UM confirmed the syringe should have been changed every 24 hours and discarded it after seeing the date on it. The resident’s orders required tube feeding via pump and daily change of the piston syringe and GT site care every 24 hours.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.