F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
E

Tube Feeding Care and Documentation Deficiencies

Arnold Walter Nursing & Rehabilitation CenterHazlet, New Jersey Survey Completed on 06-25-2026

Summary

The facility failed to follow professional standards of practice and physician orders for residents receiving enteral feedings, resulting in deficient care for three residents with feeding tubes. The report identified problems with tube feeding administration, documentation, and equipment handling for residents who had diagnoses including dysphagia, failure to thrive, stroke, diabetes, and dependence on enteral nutrition. The facility’s own tube feeding policy required feedings to be given per physician order, with tubing and piston syringes changed on specified schedules. For one resident, the surveyor observed a Glucerna 1.5 tube feeding bottle dated two days earlier while the pump was off, then later observed a new bottle running at 50 mL/hr. The resident’s record showed an order for continuous Glucerna 1.5 at 50 mL/hr via G-tube, along with orders to document oral intake on tray tickets. The medication administration audit showed the tube feed was signed as hung on consecutive evenings, but staff interviews revealed confusion about when the feed was started and how the volume was being tracked. The DON stated that when the 1,000 mL bottle emptied, staff should hang a new bottle to run the remaining 200 mL and document it when hung. For another resident, the record showed an order to check gastric residual before continuous feeding and to hold and notify the physician if residuals exceeded specified amounts. However, the eMAR had been set up with a field for temperature instead of residual, and nurses documented temperatures and completion checks rather than residual amounts for multiple days. An LPN acknowledged she had documented temperatures instead of residuals and stated she should have read the order correctly. The UM and DON both confirmed the documentation was wrong and that the nurses should have notified the physician and had the order corrected. For the third resident, the surveyor observed a heavily soiled feeding pump area, bedside table, air mattress pump, and floor with a tan substance, along with a piston syringe labeled with the resident’s room and bed number and dated two days earlier. The resident stated medications were crushed and given through the feeding tube and that staff used the syringe for medications and hydration. The UM confirmed the syringe should have been changed every 24 hours and discarded it after seeing the date on it. The resident’s orders required tube feeding via pump and daily change of the piston syringe and GT site care every 24 hours.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Unlabeled Tube Feeding Bags
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a G-tube and diagnoses including stroke and pneumonitis had tube feeding ordered at 60 ml/hr, and the care plan identified increased nutritional risk related to gastric tube use. Staff observed the tube feeding bag hanging with an additional water bag, and both bags were not labeled with the resident’s name, formula, rate, date, or time hung; an RN and an LPN confirmed the unlabeled setup.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Feeding Tube Placement Not Verified Before Use
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with quadriplegia, dysphagia, and severe cognitive impairment had a G-tube used for meds, water flushes, and enteral nutrition. An LPN administered water, meds, and formula through the tube without checking placement or residual first, and the resident's care plan and MD orders did not include instructions to verify tube placement before use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
GT Feeding Care Not Provided as Ordered
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a GT, dysphagia, Parkinson's disease, and failure to thrive was observed lying flat in bed while receiving enteral feeding and water via pump, despite orders and care plan directions to keep the HOB elevated during feeding. The water bag connected to the pump was also not labeled with the resident's name, date, and time, and an LPN confirmed both the unlabeled bag and the resident's flat positioning during the feeding.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Tube Feeding Not Dated or Timed
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with dysphagia, severe cognitive impairment, and dependence on staff for ADLs received nocturnal Jevity 1.5 via feeding tube, but the bottle was not dated or timed when opened and the tubing was undated. During observation, the feeding was running on a pump while the resident rested in bed with the HOB elevated, and an LPN and the DON confirmed the dating and timing were missing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Enteral Feeding Not Administered as Ordered
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident who depended on PEG tube feeding was ordered Jevity 1.5 at 60 mL/hr for 22 hours daily with free-water flushes, but was observed disconnected from the feeding with the pump turned off and about 1,300 mL of formula still hanging at the bedside. An LPN confirmed she had not connected the feeding and said she forgot to do so, and the DON later confirmed the enteral feeding had not been connected as ordered.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Feeding Tube Pump Left Paused and Alarming
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with dysphagia, protein-calorie malnutrition, and dementia had a GT feeding ordered to run 20 hours daily via pump. During observation, the pump was found inactive, paused, and alarming with feeding still remaining in the bottle, and an LVN said she was unaware of the alarm or why the pump was paused. The DON stated tube feedings may be paused for care or meds but should be restarted as soon as possible so the resident receives the full ordered dose.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across New Jersey

Get a heads-up on the newest immediate-jeopardy (J–L) citations in New Jersey — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.