Infection Prevention and Control Failures Across PPE, Hand Hygiene, Wound Care, Catheter Care, and Nebulizer Handling
Summary
The facility failed to provide and implement an infection prevention and control program as evidenced by multiple observations of improper PPE use, hand hygiene, wound care, catheter care, respiratory equipment handling, and lack of infection surveillance and policy review. The report identified failures involving residents on enhanced barrier precautions, residents with indwelling catheters, residents receiving wound care, and a resident using nebulizer treatments. The facility also had no tracking for surveillance of staff, visitors, or volunteers using standard or transmission-based precautions, and no documented review or revision tracking for infection prevention and control policies. During wound care for a resident with diabetes, morbid obesity, pressure ulcers, cellulitis, and multiple skin wounds, an LPN placed wound care supplies directly on the tray table without a barrier, used the same gloves while handling clean and contaminated items, and used gloved fingers to apply Triad Paste and Calmoseptine from medication cups. The same observation showed the LPN cleansing and drying multiple wound areas with the same gloves and applying products without changing gloves between tasks. The resident’s care plan and physician orders included enhanced barrier precautions and specific wound treatment instructions, including not scrubbing the wounds and using clean technique for dressing changes. Enhanced barrier precautions were not followed for residents who had signs posted on their doors and PPE available at the entrance. For one resident with a Foley catheter and wound care needs, staff wore gloves but did not wear gowns while providing peri-care and holding the resident during cleaning. For another resident with an indwelling catheter and neurogenic bladder, two nursing assistants performed catheter care while wearing isolation gowns and gloves, but the observation documented urine spilling onto the floor during drainage and paper towel use to clean the spill. Hand hygiene was also not performed for the required 20 seconds before placing a clean incontinence product on residents, and staff confirmed the hand hygiene expectation during interview. Respiratory equipment handling was also not completed according to policy for a resident receiving nebulizer treatments. The nebulizer chamber was repeatedly observed assembled and left on the bedside table, not bagged, not dated, and with liquid remaining in the chamber across multiple observations. Staff interviews confirmed that the chamber should be rinsed, dried, and stored in a dated, labeled bag after use, but the equipment remained out and uncleaned. The infection preventionist also confirmed that no surveillance tracking had been conducted for enhanced barrier precautions or transmission-based precautions, no resident chart audits were being tracked for infection signs and symptoms, and no newer review or revision of the infection prevention and control plan was known.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.