Failure to Report Skin Injury and Improper PEG Tube Medication Administration
Summary
The facility failed to ensure prompt reporting of a newly identified skin issue for a resident with stroke-related hemiplegia, atrial fibrillation, a pacemaker, hyponatremia, and dementia. The resident was dependent for care and had care plan interventions for abnormal bruising, impaired skin integrity, pain, and functional deficits. During the morning of the event, a CNA observed the resident leaning to the left in a wheelchair and adjusted her with pillows, but did not ask about pain or report the positioning concern. Later, a CNA noticed the resident’s left forearm was swollen and bruised through her shirt and notified a nurse, but the finding had not been reported during shift change. The resident was later observed with extensive dark purple bruising and swelling from above the wrist to the elbow, and she could not explain how the injury occurred. Interviews showed that multiple staff members had different accounts of when the arm condition was first noticed and whether it had been reported. One CNA stated she saw the arm swelling during morning care and did not report it because she assumed others already knew. Another CNA stated she noticed the resident leaning to the left during her shift and repeatedly repositioned her, but did not report the issue. A nurse on the day shift stated she had not observed any arm issue and had not received report about it. The nurse who responded after the finding was reported stated the arm was warm, swollen, and dark purple, and the resident winced when touched. The resident’s family member reported the facility called and said a CNA had noticed the arm swelling and discoloration, and a practitioner later told the family the injury was caused by tissue trauma. The facility also failed to properly handle and use a PEG tube for another resident who had a PEG, ASHD, GERD, dysphagia, and a history of esophageal obstruction, and who was severely cognitively impaired and dependent on care. During observed medication administration, a nurse crushed medications and mixed them together in red guaifenesin liquid for PEG administration. The nurse entered the room without a clean barrier, did not check tube placement or residuals, and did not flush the PEG before attempting administration. The medication would not drain properly, the stopcock was not positioned correctly, and medication spilled onto the bed. The nurse left the room to get help, and subsequent observation showed continued attempts to force the medication through the PEG without proper technique. The infection control nurse later agreed that the standard of care was not followed, including not mixing medications for PEG administration and not assessing or flushing the tube before use.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.