Water Management and Enhanced Barrier Precautions Failures
Summary
The facility failed to maintain an active water management plan for legionella and other opportunistic pathogens of premise plumbing. During observation, multiple water-related fixtures and areas were found inoperable or out of service, including an inoperable water fountain on the fourth floor near the elevator, inoperable hoppers in the red, green, and brown unit soiled utility rooms, a cloudy hopper bowl in the green unit, an inoperable hand sink in the green unit soiled utility room, out-of-order shower rooms in the red, blue, and green units, an inoperable utility sink in the blue unit janitor closet with a missing atmospheric vacuum breaker, and an inoperable hand sink in the blue unit nourishment room. Staff interviews confirmed several of these fixtures were not being used, and the Nursing Home Administrator stated they had not attended a water management meeting since arriving at the facility and could not locate materials related to the water management plan at the time of interview. Record review showed the facility had some water treatment service reports for the cooling tower and closed loop, but the facility’s water flow chart was incomplete, with several blank boxes and only two components identified. The report also noted that the facility’s procedure referenced completing the CDC worksheet, creating a water management team, documenting the building and water system description, identifying vulnerable areas, establishing control measures, confirming verification and validation procedures, documenting testing methods, and maintaining water heater temperatures, but the observed and reviewed materials did not show a complete active plan as described. The facility also failed to implement Enhanced Barrier Precautions for multiple residents. One resident with an artificial airway and diagnoses including malignant neoplasm of the glottis, right bronchus or lung, carcinoma in situ of the pharynx, and presence of an artificial larynx had EBP care planned, but no EBP signage was posted on the room door or wall outside the room, and staff acknowledged the missing signage. Another resident with diagnoses including surgical amputation, diabetes, acute osteomyelitis, peripheral vascular disease, dementia, and a Foley/wound order for EBP was observed receiving catheter care without the CNA wearing a gown or performing hand hygiene after care. A third resident with HIV, dysphagia, severe protein-calorie malnutrition, and a PEG tube had EBP ordered, and an LPN was observed administering medications via the PEG tube while wearing gloves but not a gown, with the LPN stating a gown should have been worn. A fourth resident with cataracts and glaucoma had eye drops handled in a way that placed the medication bottle and cap on a soiled bedside table before the bottle was returned to the medication cart, and the LPN stated a barrier should have been used or the bottle sanitized before returning it.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.