F0880 F880: Provide and implement an infection prevention and control program.
F

Infection Control Failures in Water Management, Ice Scoop Storage, and Enhanced Barrier Precautions

Royalton Manor, LlcSt Joseph, Michigan Survey Completed on 07-09-2026

Summary

The facility failed to maintain an active and ongoing plan for reducing the risk of legionella and other opportunistic pathogens of premise plumbing. On 7/7/26, surveyors observed a water line coming down from the ceiling in the kitchen and extending about 10 feet to the back of the cookline, with nothing hooked up to it or using it. The same day, in the South janitors' closet, hot water from a fixture initially discharged discolored water before running clear. Maintenance staff stated the South spa was not used often, that residents had private showers in their rooms, and that the spa and South personal showers were not regularly flushed. Surveyors also observed a hopper in the central soiled utility with the spray turned off and a mop sink in the central soiled linen room with the cold water turned off. Maintenance staff stated he was unaware of the unused water line on the cookline and that it was not currently flushed. Record review of the Water Management Team Meeting Minutes dated 6/11/26 showed the section for evaluating water cloudiness or turbidity was left blank, and the flushing documentation did not include a list or map of fixtures that were flushed. The facility also failed to maintain hydration carts' ice scoop holders in a sanitary condition. On multiple observations from 7/7/26 through 7/9/26, hydration carts in the 200s hallway and outside a resident room had cracked plastic ice scoop holders with white and brown debris inside, and later pink material was seen on the interior of the cracked holder. The Infection Preventionist stated that if an ice scoop holder was cracked it should be thrown out, that kitchen staff should clean the carts and scoops after nurse aides returned the carts each shift, and that cracked holders could harbor bacteria. The facility further failed to ensure staff used appropriate PPE and that enhanced barrier precautions were in place for two residents. One resident had a care plan for straight catheterization every 6 hours with enhanced barrier precautions during high-contact care. During observation, an RN entered the room, donned gloves, and performed a bladder scan and catheterization without putting on a gown; the RN later stated she should have worn one but forgot. A family member reported seeing staff not wearing proper PPE during care. Another resident had a history of MRSA and a care plan calling for enhanced barrier precautions, but no PPE cart or signage was present outside the room and two CNAs provided brief-change care without gowns. The Infection Preventionist stated residents with prior MDRO infection should remain on enhanced barrier precautions and confirmed the resident should have had new isolation orders after treatment ended, but this had been overlooked and not implemented.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Infection Control Practices Not Consistently Implemented for Resident Evaluated for C. difficile
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident being evaluated for C. difficile was not consistently managed under the correct contact-enteric precautions. Staff gave care with incomplete understanding of the precautions, the room signage did not clearly identify the needed disinfectant or contact time, bleach wipes were not always available, and staff were observed missing hand hygiene and handling items under PPE during care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use EBP PPE During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to Use EBP PPE During Wound Care: A resident with a wound and severely impaired cognition was receiving ordered wound care when the DON and ADON entered the room, washed hands, and donned gloves but did not wear gowns before starting care. EBP signage and PPE were present at the bedside, and both leaders later stated they forgot to put on gowns even though the resident was on EBP for an open wound and the facility policy required gown and glove use for wound care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Enhanced Barrier Precautions and Hand Hygiene During Resident Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Staff failed to consistently follow EBP and hand hygiene for two residents who required high-contact care. One resident with an indwelling catheter and cognitive impairment did not have EBP followed during transfers, clothing removal, and pericare, and another resident with a suprapubic catheter and multiple pressure ulcers had staff wear PPE incorrectly, remove PPE in the room without hand hygiene, and continue care after emptying the catheter bag without changing gloves or cleaning hands. Interviews confirmed staff were expected to use gowns, gloves, and hand hygiene for these tasks.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use Required PPE for Resident on Contact Precautions
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident on Contact Precautions for active C. difficile infection was not consistently protected by required PPE. Although signage outside the room directed all entrants to wear a gown and gloves, an RN entered the room with medications without either item and touched the bedside table and door surface. The resident stated staff did not always wear gowns, and the DON confirmed staff were expected to wear a gown and gloves when entering the room while precautions were in place.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses During Incontinence and Ostomy Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A facility failed to maintain infection control during care for two residents. During incontinence care, a CNA removed gloves and applied clean gloves without hand hygiene before placing a clean brief on a resident who was dependent for toileting hygiene and always incontinent. During ostomy care, an LVN handled a resident’s colostomy, wiped stool from the stoma, and continued care without removing soiled gloves, sanitizing hands, or putting on clean gloves. The DON stated staff were expected to perform hand hygiene between glove changes.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Incontinent Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control Failures During Incontinent Care: Two residents were observed receiving incontinent care with multiple infection control lapses. A CNA did not perform hand hygiene between glove changes or after glove removal while caring for one resident, and another CNA did not wash hands before care, changed nothing between dirty and clean tasks, touched clean items with dirty gloves, placed soiled linens on the floor, and handled dirty linens with bare hands after glove removal. The DON stated hand hygiene, glove changes, and proper handling of soiled linens were required, and facility policies reflected those practices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Michigan

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Michigan — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.