Infection Control, Water Management, and Enhanced Barrier Precautions Failures
Summary
The facility failed to maintain an active water management program for reducing the risk of legionella and other opportunistic pathogens of premise plumbing. During observation, a hand sink in the emergency food and water storage room was covered with a plastic board and had the hot and cold water turned off. In the laundry room, a residential washing machine had intact water lines and an out-of-order sign, and a laundry aide stated it had been out of order for one or two months. Another residential washing machine was covered with a towel, and the aide stated it worked but they did not like to use it. In the south hall soiled linen room, a hopper had the hot water faucet turned off with a sign stating do not use, and a nonfunctional hand sink with foot pedal attachments was observed, indicating possible stagnant water in the line. The cold water was also off at a hand sink in the south hall supply room. Additional observations found discolored water coming from the hopper cold water faucet in the north hall soiled utility room for a few seconds before running clear, and the spray hose attachment dripped discolored water when turned upside down. A nonfunctional hand sink with an out-of-order sign was also observed in the north hall supply room. The maintenance supervisor stated the facility’s water management team met quarterly, kept boilers above 140 degrees F, tested for legionella yearly, and had ordered chlorine tests to begin testing chlorine residual. He also stated empty rooms were flushed quarterly, but hoppers were not part of the flushing schedule. Later, a nonfunctional hand sink in the north hall soiled linen room was identified as clogged and had been out of order for two weeks. In the emergency food and water room, a nonfunctional hand sink was observed after the water had been turned off because the room was used as storage. In an unoccupied room, discolored water discharged briefly from the bathroom hand sink before running clear, and another hand sink in that room had an out-of-order sign dated 2/7/21 and was nonfunctional when turned on. The maintenance supervisor stated the water to that sink had been turned off because it was not being used. The facility’s water management program and risk assessment did not include hoppers and nonfunctional fixtures still connected to the water line, and a flow diagram and control limits were not identified. The facility also failed to consistently implement a comprehensive infection control program with proper surveillance and trend identification. The DON and LPN/IP stated that documentation for infection identification, tracking, monitoring, analysis of surveillance data, and follow-up activity was not available for May 2025 through December 2025. The DON stated it was important to have a consistently implemented and comprehensive infection program to be aware of infections in the facility, preempt outbreaks, detect patterns, and proactively address outbreaks. The facility policy stated that a surveillance system would be used for prevention, identifying, reporting, investigating, and controlling infections and communicable diseases, but the requested surveillance documentation was not available. The facility also failed to ensure infection control practices were followed for one resident on enhanced barrier precautions. The resident had diagnoses including paraplegia, muscle weakness, neuromuscular dysfunction of bladder, urinary retention, UTI, pressure ulcer of the sacral region, and hypertension, and was dependent on staff for all ADLs with no cognitive impairment noted on the MDS. The resident’s physician orders included enhanced barrier precautions. During observation, a CNA entered the resident’s room with linens and cleaning wipes without performing hand hygiene or donning PPE. The CNA later re-entered the room after retrieving gloves and gauze from a hallway cabinet, and then exited carrying soiled linen and cleaning wipes. The resident stated the CNA had provided care after a bowel movement and did not wear a gown. The CNA stated he did not wear a gown during the care, knew he should have, and said he looked for PPE signage to know when PPE should be donned. The resident’s care plan did not include interventions for enhanced barrier precautions, and the facility policy stated PPE for enhanced barrier precautions is required for high-contact care activities such as changing briefs or assisting with toileting.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.