Failure to Follow Water Management and Infection Control Practices
Summary
The facility failed to implement its infection prevention and control program, including its water management plan and required infection control practices. During observation, multiple water-related fixtures were found in disrepair or showing signs of low use, including inoperable water fountains on the second floor outside the dining room and in the first floor physical therapy room, a toilet with low water level and debris in the first floor west transitional rehabilitation tub room, a toilet with a film-like substance on the water surface and a nonfunctional hand sink in the first floor west transitional rehabilitation shower room, a hopper bowl with no water in the second floor soiled utility room, and a hopper with a nonfunctional flush apparatus in the third floor soiled utility room. The Maintenance Supervisor stated the annual review had not been completed, that chlorine was tested quarterly with a pool test kit, that the boiler domestic water was set to 119 degrees F, and that unoccupied rooms were flushed only for sinks and not toilets. Record review showed the facility’s water management binder included policies approved on 1/21/26 and a document describing key Legionella control activities, including identifying areas where Legionella could grow and spread, establishing control measures, and preventing water stagnation. The binder also referenced CDC guidance stating that low-flow piping runs and dead legs should be flushed at least weekly and infrequently used fixtures such as eyewash stations and emergency showers should be flushed regularly. Interviews with the NHA, DON, and Dietary Manager showed inconsistent understanding of the water management team and its responsibilities, and the Dietary Manager stated they did not perform tasks related to Legionella. The Maintenance Supervisor also stated some drinking fountains had been broken and turned off for awhile, and eyewash stations were flushed only every couple of months. The facility also failed to follow infection control practices for resident care. During morning medication administration, an LPN used an Accu-Chek meter to check a resident’s blood sugar and returned the meter to the med cart without sanitizing it after use. The LPN later stated the meter should have been wiped off and sanitized after use, and the DON agreed that the meter should be disinfected after each use by all nurses. In a separate observation, two staff members were providing care to a resident with enhanced barrier precautions in place, but the door signage did not identify which resident required the precautions and neither staff member was wearing the required PPE. The resident had diagnoses including Parkinson’s disease, hypertension, chronic kidney disease, gastrostomy, type II diabetes, and dementia, and the record showed orders for enhanced barrier precautions related to a PEG tube and wound. The resident’s care plan directed staff to wear gown and gloves during high-contact care activities and to use hand hygiene before and after resident contact, including before applying and after removing PPE.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.