Infection Control Program Not Fully Implemented
Summary
The facility failed to implement and operationalize a comprehensive infection prevention and control program. Survey observations and record review showed that infection surveillance data were incomplete and inconsistent, with the infection control staff unable to clearly identify trends, causative organisms, symptom onset dates, or the type and timing of transmission-based precautions for several residents. The monthly infection control summary, line list, and mapping tool for December 2025 contained discrepancies in the number of infections documented, and the infection control staff stated that potential infections not treated with antimicrobials were not tracked. During dining observations, staff served residents in the main dining room and during hallway tray pass without performing hand hygiene between residents, and residents were not offered hand hygiene before or after meals. The facility’s dining guideline and hand hygiene policy stated that staff should perform hygienic practices and that residents should be offered hand sanitizer, including before and after assisting with meals. Staff were observed passing trays, removing lids, applying clothing protectors, and moving from one resident to the next without hand sanitation. For Resident #12, who had a PICC line and TPN, staff were observed providing IV medication administration while wearing gloves but not a gown, despite an EBP sign posted at the room entrance. The same resident was later observed receiving PICC care and assessment of a colostomy bag, abdominal wound dressing, and peri-area without a gown and without hand hygiene after removing gloves and before donning new gloves. The DON and infection control staff stated that gown and gloves should be worn for PICC lines, wounds, catheters, and ostomies, and that hand hygiene should occur after glove removal. Glucose meter cleaning was not performed between resident blood sugar checks. An RN used the same glucometer for multiple residents, placed it in a clear plastic cup with supplies, and returned to the medication cart to document results without cleaning or disinfecting the device. The facility policy required shared glucometers to be cleaned and disinfected after every use and between each resident. In addition, Resident #11’s urinary catheter tubing and drainage bag were observed on the floor while the resident was in bed, and staff and the DON observed the condition. Staff stated that a urinary catheter bag or tubing should not be on the floor, and the infection control preventionist acknowledged that staff had not been educated to use a barrier from the floor.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.