Inadequate fall supervision and unsafe lift transfers
Summary
The facility failed to provide adequate supervision and meaningful fall interventions for a resident with a history of falls and serious injuries. R24 was admitted with diagnoses including anxiety, nondisplaced fracture, and chronic pain. After an initial fall on 6/4/2026, the resident was found on the bedroom floor with her back against the bed, complained of head pain, and was sent to the emergency room. The facility added a motion sensor in the resident’s room as a new fall intervention, but the care plan did not specify where the sensor should be directed or when staff should verify that it was functioning appropriately. R24 later fell again and was found on the floor on her left side with a large gouge on her forehead and a pool of blood on the floor. The incident investigation documented that the resident likely fell asleep while seated in her wheelchair and then fell forward onto the floor. The resident’s care plan reflected that she had been readmitted after hospitalization for a fall that caused a subarachnoid hemorrhage, fractures of the odontoid process and L3, facial lacerations, a Type II dens fracture, and pleural effusion. During interview and observation, the NHA stated the motion sensor had not functioned for the incident because it was pointed above the resident’s head rather than toward her, and the alarm was observed mounted on the wall pointing toward the window and about 4 feet from the floor, which was inconsistent with the manufacturer’s placement directions. Staff interviews showed they were not monitoring the alarm’s function and did not hear it sound during the morning of the fall. The RN unit manager reported no memory of hearing the alarm and was unsure how its function was monitored. The charge RN and CNA reported they had not heard the alarm sound and were not aware the resident even had a motion sensor until after the fall; the CNA also observed that the alarm was pointing toward the bed rather than toward the resident. The facility policy required proper application and functioning of alarm devices, and the manufacturer’s instructions described specific placement for effective detection. The facility also failed to safely perform lift transfers for another resident. R76, who had dementia, abnormal posture, muscle weakness, and unsteady gait, was observed during two separate transfers using a full-body lift. On both occasions, CNAs began moving the resident before his body was fully suspended off the bed, and they did not verify that the sling loops remained secured before moving him. During the first observation, the lift legs were not moved to the fully open position before lifting and moving the resident. Staff stated they were not aware of the safety requirements for the lift and denied training on the equipment. The DON later confirmed the safety concerns after the observations were shared.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.