F0880 F880: Provide and implement an infection prevention and control program.
F

Infection Control Failures With Legionella, Linen Handling, Equipment Cleaning, Hand Hygiene, and PPE

Warren Barr South LoopChicago, Illinois Survey Completed on 04-24-2026

Summary

The facility failed to follow its Water Management Program after a water specimen from the 3rd Floor East shower handheld tested positive for Legionella pneumophila serogroup 1. The outside vendor’s report stated that the facility’s testing showed declining performance of water supply controls and recommended actions related to the positive result. The maintenance director stated that corrective actions were done around 04/09/2026, but retesting had not yet been completed. The facility’s Water Management Plan stated that if Legionella growth appears uncontrolled, the plan should be reevaluated and verification water testing repeated within 48 hours if remedial treatment is performed. The facility failed to maintain clean towels in the laundry room free from contamination. On observation, a metal table in the laundry area held clean towels on the clean side of the room, while a white trash bin was also present in the clean area. Navy blue foam pads and triangular foams were stored below the towels; they were visibly dusty, and dust fell to the floor when touched. The housekeeping director stated that the foams needed to be clean and should not be near the towels because they could cause contamination. The facility policy stated that clean linens are to be protected from the environment. The facility also failed to keep resident care items and infection control practices consistent for multiple residents. One resident with diagnoses including viral pneumonia and respiratory disorder had inhalers on a bedside table and a nebulizer mask placed on a high-touch surface next to the bed; the nurse stated the mask should have been in the bag, and the DON stated inhalers should not be on the bedside. A nurse used the same wrist blood pressure monitor, thermometer, and pulse oximeter on four residents without disinfecting the equipment between residents and did not perform hand hygiene or use gloves during the medication/vital sign care. For another resident on enhanced barrier precautions with a tracheostomy and other serious diagnoses, staff did not don PPE when entering the room despite signage posted on the door. In addition, dirty linen was observed on the floor in a resident room, and the DON stated soiled linen bags should not be placed on the ground because it can spread microorganisms.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Infection Control Practices Not Consistently Implemented for Resident Evaluated for C. difficile
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident being evaluated for C. difficile was not consistently managed under the correct contact-enteric precautions. Staff gave care with incomplete understanding of the precautions, the room signage did not clearly identify the needed disinfectant or contact time, bleach wipes were not always available, and staff were observed missing hand hygiene and handling items under PPE during care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use EBP PPE During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to Use EBP PPE During Wound Care: A resident with a wound and severely impaired cognition was receiving ordered wound care when the DON and ADON entered the room, washed hands, and donned gloves but did not wear gowns before starting care. EBP signage and PPE were present at the bedside, and both leaders later stated they forgot to put on gowns even though the resident was on EBP for an open wound and the facility policy required gown and glove use for wound care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Enhanced Barrier Precautions and Hand Hygiene During Resident Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Staff failed to consistently follow EBP and hand hygiene for two residents who required high-contact care. One resident with an indwelling catheter and cognitive impairment did not have EBP followed during transfers, clothing removal, and pericare, and another resident with a suprapubic catheter and multiple pressure ulcers had staff wear PPE incorrectly, remove PPE in the room without hand hygiene, and continue care after emptying the catheter bag without changing gloves or cleaning hands. Interviews confirmed staff were expected to use gowns, gloves, and hand hygiene for these tasks.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use Required PPE for Resident on Contact Precautions
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident on Contact Precautions for active C. difficile infection was not consistently protected by required PPE. Although signage outside the room directed all entrants to wear a gown and gloves, an RN entered the room with medications without either item and touched the bedside table and door surface. The resident stated staff did not always wear gowns, and the DON confirmed staff were expected to wear a gown and gloves when entering the room while precautions were in place.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses During Incontinence and Ostomy Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A facility failed to maintain infection control during care for two residents. During incontinence care, a CNA removed gloves and applied clean gloves without hand hygiene before placing a clean brief on a resident who was dependent for toileting hygiene and always incontinent. During ostomy care, an LVN handled a resident’s colostomy, wiped stool from the stoma, and continued care without removing soiled gloves, sanitizing hands, or putting on clean gloves. The DON stated staff were expected to perform hand hygiene between glove changes.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Incontinent Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control Failures During Incontinent Care: Two residents were observed receiving incontinent care with multiple infection control lapses. A CNA did not perform hand hygiene between glove changes or after glove removal while caring for one resident, and another CNA did not wash hands before care, changed nothing between dirty and clean tasks, touched clean items with dirty gloves, placed soiled linens on the floor, and handled dirty linens with bare hands after glove removal. The DON stated hand hygiene, glove changes, and proper handling of soiled linens were required, and facility policies reflected those practices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Illinois

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Illinois — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.