Improper LAL Mattress Layering and Incorrect Weight Setting
Summary
The facility failed to ensure that low air loss (LAL) mattresses were not layered with multiple linen layers for four residents, and failed to ensure one resident’s LAL mattress was set at the correct weight setting. The report identifies residents R61, R87, R134, and R191 as being at risk for pressure ulcers, with all four observed on LAL or air loss mattresses with more linen layers than the facility’s stated expectation. The report also documents that R87’s mattress setting did not match the resident’s recorded weight. R134 had diagnoses including pressure ulcer of the right ankle, chronic kidney disease, diabetes mellitus, and dementia, and was unable to be interviewed due to altered mental status. Her Braden Scale score was 12, indicating high risk for pressure ulcers. Her care plan documented that she was on an air mattress with heel protectors, and wound documentation showed a chronic Stage 3 sacral pressure injury and a Stage 3 right lateral ankle pressure injury, both not healed. On observation, R134 was lying on her back on a LAL mattress with a top sheet, incontinence pad, and a quadruple-folded top sheet, creating six linen layers under her body. The wound care nurse stated that the recommended layering on a LAL mattress was one flat sheet and either one pad or one brief. R61 was observed in bed on an air loss mattress with a fitted sheet, bed pad, and incontinence brief. The resident was awake with some confusion and unable to answer questions, and the MDS indicated dependence or substantial/maximal assistance for all ADL needs. The resident had an active wound in the care plan, and the Braden Scale score of 12 indicated a problem with friction and shear. R191, who had dementia and other diagnoses including a prior right femur fracture and muscle weakness, had a BIMS score of 3 and required substantial/maximal assistance for most ADLs. R191 was observed sleeping on an air loss mattress with a fitted sheet, bed pad, and incontinence brief, and wound consultation documented an active wound with a recommendation for a pressure reducing mattress. R87 had morbid obesity, a Stage 3 pressure ulcer, osteomyelitis, and hypertension, and was cognitively intact per MDS. She was observed on a LAL mattress with a flat sheet, incontinent pad, and incontinent brief between her skin and the mattress. The mattress setting was on level 9, which staff described as about 375 lbs, while the resident’s recorded weight was 299.2 lbs. The wound care nurse stated the setting should match the resident’s weight and that the purpose of the setting was to prevent skin breakdown and pressure ulcers.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.