Failure to Follow Ordered Ventilator and Oxygen Therapy, and Incomplete Nebulizer Monitoring
Summary
The facility failed to follow physician orders for ventilator settings for two residents who were tracheostomy and ventilator dependent. One resident had a physician order dated 04/10/26 for a ventilator rate of 20, but during trach care the ventilator was observed at a rate of 22, and the RT confirmed the resident was not receiving the ordered settings. Another resident had physician orders for vent settings of rate 24, tidal volume 450, and oxygen at 35%, but observations on two separate days showed settings of rate 22, tidal volume 400, and oxygen at 40%. The RT confirmed the resident was not receiving the ordered vent settings and stated the resident had returned from the hospital on hospital vent settings, while the DON acknowledged the resident’s vent settings should match the physician’s orders. The facility also failed to follow physician orders for oxygen therapy for two residents. One resident had an order for continuous oxygen via nasal cannula at 3 L/min with oxygen saturation to remain above 90%, but the oxygen concentrator was observed set at 4.5 L/min, then 3.75 L/min, and later a portable tank was observed at 4.0 L/min during therapy. The resident stated he could not reach the concentrator and denied adjusting it. Staff interviews showed the RT stated the concentrator flow meter should be set to the ordered amount and that oxygen would only be increased temporarily if the resident had signs or symptoms of respiratory distress or low oxygen saturation. Another resident had physician orders for oxygen at 2 L/min via nasal cannula, but repeated observations showed the oxygen concentrator set at 3 L/min and 3.5 L/min. The resident stated no one had touched the machine, and the record review showed the documented oxygen flow rate remained at 2 L/min. Staff interviews indicated that only RTs adjust oxygen flow meters and that nurses check and document the ordered oxygen delivery during shifts. In addition, during nebulizer therapy for this same resident, the RT did not read and check the medication label or expiration date, placed the mask on the resident, and left the room for about 3 minutes while the tubing disconnected from the mask. The resident attempted to reconnect the tubing while the RT was absent, and the RT returned afterward and reattached it.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.