Infection Prevention and Control Failures
Summary
Hand hygiene was not offered or reminded to residents before lunch service or eating. During observation and interview, residents stated staff had not offered to clean or wash their hands before meal trays were served, and one resident said he would wash his hands himself. Another resident and her roommate were observed eating at bedside, and the Director of Rehabilitation brought hand wipes into the room and wiped both residents’ hands after the concern was raised. Additional residents in the hallway stated staff had not reminded them to wash or sanitize their hands before lunch, and several said staff had never offered to do so before meals. Two CNAs assigned to those rooms confirmed they had not offered hand hygiene to their residents that day, and the Infection Preventionist stated staff were expected to offer hand hygiene before meal trays were served. The facility policy stated hand hygiene is the primary means to prevent the spread of infection and is required before eating. Resident glucometers were not sanitized using the appropriate disinfecting agent. During observation, an LPN removed a glucometer from a medication cart, obtained a blood sample from a resident, and cleaned the device with wipes from a Super Sani-cloth container before immediately returning it to the drawer. The LPN stated she was unaware the glucometer surface needed to remain visibly wet for at least two minutes for the germicide to be effective. Another nurse stated Sani-cloth Plus wipes were used to clean glucometers, and the Infection Preventionist stated glucometers should be cleaned after each use. The facility’s Assure Platinum glucometers were identified as the devices in use, and the manufacturer’s manual specified Super Sani-cloth Germicidal Disposable wipes as the recommended wipes for cleaning and disinfecting the glucometers. The facility’s glucometer cleaning instructions also directed staff to use Super Sani-cloth wipes and allow a 2-minute wet time. The facility did not maintain an Infection Prevention and Control Program binder that could be located at either nurse’s station, and the Administrator could not provide documented evidence that the program had been reviewed at least annually. Oxygen concentrators for residents with COPD had visible dust and debris, including dust buildup in the vent of one concentrator and brown dirt and dust buildup on another resident’s oxygen condenser filter. The DON stated the Treatment Nurse was responsible for changing tubing and humidifiers and cleaning the filters, and the IP stated dusty filters were a concern because of inhaling dust, oxygen concentration issues, and infection possibilities. In addition, a resident with COPD and pneumonia was observed coughing in her room without a mask for source control while sharing the room with two roommates. Records showed she had been prescribed doxycycline for left lower lobe pneumonia and COPD exacerbation, and the CDC guidance cited in the report stated droplet precautions are used for patients known or suspected to be infected with pathogens transmitted by respiratory droplets and that source control includes placing a mask on the patient.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.