F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
D

G-tube Placement Order Not Properly Transcribed or Documented

Edenbrook LakesideMilwaukee, Wisconsin Survey Completed on 04-07-2026

Summary

The facility did not ensure appropriate treatment and services for a resident with a gastrostomy tube. The resident had diagnoses including dementia and acute cystitis with hematuria, and the MDS documented a BIMS score of 00, indicating severe cognitive impairment. The resident was dependent on staff for all ADLs, incontinent of bowel and bladder, and had impairment on both sides in the upper and lower extremities. A physician order required the resident’s G-tube length to be measured every shift for placement verification, with the tube length documented as 16 inches plus or minus 1 cm, and another order required visual inspection of the initial mark on the tube. During observation, an RN administered tube feeding and stated the tube was checked by measuring tape on the wall and charted as complete, but also stated the resident’s tube did not have a visible tic mark. The facility policy required the tube to be marked, the length measured and documented, and the mark visually inspected before access. Record review showed the order to measure the tube length was not transcribed into the MAR/TAR, so nursing staff could not accurately monitor placement using the specific measurement. The MAR/TAR documented the visual inspection order inconsistently, with yes and no entries, and the tube length itself was not documented. The ADON and DON confirmed the measurement order was missing from the MAR/TAR and that there was no documentation showing the tube length and placement were being monitored as ordered.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Unlabeled Tube Feeding Bags
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a G-tube and diagnoses including stroke and pneumonitis had tube feeding ordered at 60 ml/hr, and the care plan identified increased nutritional risk related to gastric tube use. Staff observed the tube feeding bag hanging with an additional water bag, and both bags were not labeled with the resident’s name, formula, rate, date, or time hung; an RN and an LPN confirmed the unlabeled setup.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Feeding Tube Placement Not Verified Before Use
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with quadriplegia, dysphagia, and severe cognitive impairment had a G-tube used for meds, water flushes, and enteral nutrition. An LPN administered water, meds, and formula through the tube without checking placement or residual first, and the resident's care plan and MD orders did not include instructions to verify tube placement before use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
GT Feeding Care Not Provided as Ordered
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a GT, dysphagia, Parkinson's disease, and failure to thrive was observed lying flat in bed while receiving enteral feeding and water via pump, despite orders and care plan directions to keep the HOB elevated during feeding. The water bag connected to the pump was also not labeled with the resident's name, date, and time, and an LPN confirmed both the unlabeled bag and the resident's flat positioning during the feeding.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Tube Feeding Not Dated or Timed
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with dysphagia, severe cognitive impairment, and dependence on staff for ADLs received nocturnal Jevity 1.5 via feeding tube, but the bottle was not dated or timed when opened and the tubing was undated. During observation, the feeding was running on a pump while the resident rested in bed with the HOB elevated, and an LPN and the DON confirmed the dating and timing were missing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Enteral Feeding Not Administered as Ordered
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident who depended on PEG tube feeding was ordered Jevity 1.5 at 60 mL/hr for 22 hours daily with free-water flushes, but was observed disconnected from the feeding with the pump turned off and about 1,300 mL of formula still hanging at the bedside. An LPN confirmed she had not connected the feeding and said she forgot to do so, and the DON later confirmed the enteral feeding had not been connected as ordered.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Feeding Tube Pump Left Paused and Alarming
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with dysphagia, protein-calorie malnutrition, and dementia had a GT feeding ordered to run 20 hours daily via pump. During observation, the pump was found inactive, paused, and alarming with feeding still remaining in the bottle, and an LVN said she was unaware of the alarm or why the pump was paused. The DON stated tube feedings may be paused for care or meds but should be restarted as soon as possible so the resident receives the full ordered dose.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Wisconsin

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Wisconsin — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.