Unsafe Hot Water Temperatures in Resident Rooms and Shared Bathrooms
Summary
The facility failed to maintain safe hot water temperatures in occupied resident rooms and shared bathrooms. Facility policy stated the maximum water temperature for sinks was 120 degrees, but surveyors found multiple resident room bathroom sinks measuring above that limit, including 140 degrees Fahrenheit in shared bathrooms for rooms 301, 302, 303, 306, 308, 503, 506, and 512, 127.2 degrees in one resident room, 143.2 degrees in two other resident rooms, 124.9 degrees in another shared restroom, and 122.4 degrees in two additional shared restrooms. The facility administrator was present during temperature testing and confirmed the facility did not have a temperature control valve for hot water. Resident 30 had severe vascular dementia with mood disturbance and a BIMS score of 0, indicating severe cognitive impairment. Resident 30 was independent with mobility and was observed going into the bathroom independently to change an incontinent brief. Resident 28 had diagnoses including multiple sclerosis, major depressive disorder, Alzheimer's disease, and senile degeneration of the brain, with a BIMS score of 2 indicating severe cognitive impairment. Resident 28 was independent with manual wheelchair mobility and was observed independently entering the bathroom and positioning herself facing the sink. The Maintenance Supervisor stated that one sink had been 160 degrees the prior week and that the hot water heater had been turned down, but the temperature was not rechecked afterward to determine whether it remained unsafe. Staff reported that water temperature was checked only weekly and that during showers they used the back of the hand and then had the resident check with the back of the hand. The Maintenance Supervisor also confirmed that the facility's infrared thermometer was used for testing hot water temperatures, while the Administrator later stated that the infrared thermometer was not appropriate for water temperature testing. The Director of Nursing confirmed that resident room hot water temperatures should not have been over 120 degrees Fahrenheit and bath house hot water temperatures should not have been over 110 degrees Fahrenheit.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.