Failure to Follow EBP, Store Respiratory Equipment, Perform Surveillance, and Disinfect Glucometer Properly
Summary
Enhanced barrier precautions were not followed for a resident with a tracheostomy, PEG tube, and Foley catheter who also had severely impaired cognition and was dependent on staff for care. During observation, staff provided high-contact care including Foley catheter care, PEG site dressing care, and cleaning of loose stool from the resident’s buttocks while no gowns or masks were worn. The resident was observed lying in bed with eyes closed and remained lethargic and non-responsive to his name while staff continued direct care without using the enhanced barrier precautions identified in the resident’s care plan. The resident’s room also contained respiratory and suction equipment that was not properly stored or maintained. A suction canister with straw-yellow drainage was observed on the nightstand with tubing attached, and the open end of the suction tubing was left in or near a trash can with visible debris or uncovered on the nightstand during different observations. A nebulizer mask and chamber were also observed out in the open on the bedside table or resting on a paper towel rather than being stored clean and dry. Staff interviews reflected that suction and nebulizer equipment not in use should be stored dry, clean, bagged, and labeled, but the equipment remained out of proper storage during the observations. Infection control surveillance and rounding data were not being performed for all residents and areas of the facility. Review of the infection surveillance binder from August 2025 through March 2026 showed missing rounding/audit documentation for areas such as the kitchen, laundry, medication rooms, dining rooms, therapy gym, resident rooms, and enhanced barrier precaution rooms, with only limited audits found in some months. The Infection Preventionist stated that housekeeping rounding had not yet been completed for May 2026, and computer review did not locate additional surveillance documentation or analysis. In addition, a nurse disinfected a blood glucose meter with an alcohol swab and placed it in a medication cart drawer, while the DON stated the meter should be disinfected with a purple-top product. The facility’s infection prevention and control program policy required surveillance, monitoring of infection prevention practices, and proper storage and maintenance of supplies, but the observed practices did not match those requirements.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.